2012
DOI: 10.1016/j.chroma.2012.06.081
|View full text |Cite
|
Sign up to set email alerts
|

Simulation model for overloaded monoclonal antibody variants separations in ion-exchange chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
26
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 56 publications
(28 citation statements)
references
References 32 publications
1
26
0
Order By: Relevance
“…Although the B value is not identical to the protein net charge of the protein, the pH dependence of parameter B follows the protein titration curve. The pH dependence of B can be modeled using purely empirical correlations or correlations based on a protein net charge model . The empirical correlations resulted in a reasonable good description of the pH dependence of B although the titration curve behavior cannot be approximated by these empirical correlations.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Although the B value is not identical to the protein net charge of the protein, the pH dependence of parameter B follows the protein titration curve. The pH dependence of B can be modeled using purely empirical correlations or correlations based on a protein net charge model . The empirical correlations resulted in a reasonable good description of the pH dependence of B although the titration curve behavior cannot be approximated by these empirical correlations.…”
Section: Resultsmentioning
confidence: 99%
“…Nonstoichiometric ion‐exchange models based on a plane–sphere geometry with homogeneous charge density on the stationary phase and the protein neglect such binding orientations. These rather simple models have provided comparable predictions of trends in adsorption equilibrium for the more detailed models because of Boltzmann‐weighted averaging of the configuration‐dependent energies .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In both cases, the model parameters are regressed to a limited number of experimental measurements. For ion exchange chromatography several isotherm models are available including Langmuir [1][2][3][4][5], steric mass action (SMA) [6][7][8], and statistical thermodynamic (ST) models [9][10][11]. Similarly, various rate models are available including models that assume the adsorption is kinetically limited, lumped rate models based on a linear driving force approximation, and the general rate model that describes the detailed mechanisms associated with diffusional mass transfer [12][13][14].…”
Section: Introductionmentioning
confidence: 99%
“…In addition to the capability of mechanistic models in downstream process development, they have also been used for monitoring of biopharmaceuticals and their impurities. For example, monoclonal antibodies and their variants have been modeled in size exclusion chromatography, cation exchange chromatography, and hydrophobic interaction chromatography . The agreement of these mechanistic models with experimental data demonstrates their potential as monitoring tools.…”
Section: Introductionmentioning
confidence: 99%