2021
DOI: 10.1016/j.msea.2021.141148
|View full text |Cite
|
Sign up to set email alerts
|

Simulation and measurement of residual stress and warpage in a HgCdTe-based infrared detector at 100 K

Abstract: A thermomechanical analysis on a 320 × 256, 30 μm pitch, middle wave infrared detector operating at 100 K is conducted. The stress induced in the HgCdTe single crystal layer needs to be minimized to avoid electro-optical perturbations and the planarity of the detector has to respect strict optical requirements. The work includes stress determination by X-ray-diffraction (XRD), warpage measurements with laser scanning, analytical calculation and finite-element modelling. The hybridized detector is studied both … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 32 publications
(39 reference statements)
0
2
0
Order By: Relevance
“…Moreover, even if excessive thermal expansion occurs, the bonding reliability is not significantly affected because the low modulus causes less thermal stress. [24,[43][44][45] Therefore, unlike Cu/SiO 2 , the surface treatment process and cleaning process during the bonding process are less demanding. In addition, the modulus of the polymer is less than 3 GPa.…”
Section: Defect and Warpage Tolerancementioning
confidence: 99%
“…Moreover, even if excessive thermal expansion occurs, the bonding reliability is not significantly affected because the low modulus causes less thermal stress. [24,[43][44][45] Therefore, unlike Cu/SiO 2 , the surface treatment process and cleaning process during the bonding process are less demanding. In addition, the modulus of the polymer is less than 3 GPa.…”
Section: Defect and Warpage Tolerancementioning
confidence: 99%
“…For optimal electro-optical performance, sensor array should be cooled down to cryogenic operating temperature. However, thermal expansion mismatch between the HgCdTe sensor array, Si-based ROIC, carrier ceramic, epoxy and adhesive materials can cause degradation of the sensor array's performance [8], [9]. In order to avoid any performance loss, the integration process of MCT sensor array to Dewar should be optimized properly.…”
Section: General Overview and Electro-optical Performancementioning
confidence: 99%