Simulation and design of 500 kV DC cable terminal accessory based on ZnO varistor microsphere composites

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
9
0
1

Year Published

2021
2021
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 16 publications
(10 citation statements)
references
References 22 publications
0
9
0
1
Order By: Relevance
“…1 Owing to the excellent overall performance of cross-linked polyethylene (XLPE) insulation, the highest operating voltage of AC XLPE cable is up to 500 kV. 2 In recent developments, a ±640 kV DC XLPE cable has been developed and passed the qualification tests. 3 However, with the continuous increase of transmission capacity, further improvement of the electrical properties of XLPE materials is urgently needed.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…1 Owing to the excellent overall performance of cross-linked polyethylene (XLPE) insulation, the highest operating voltage of AC XLPE cable is up to 500 kV. 2 In recent developments, a ±640 kV DC XLPE cable has been developed and passed the qualification tests. 3 However, with the continuous increase of transmission capacity, further improvement of the electrical properties of XLPE materials is urgently needed.…”
Section: Introductionmentioning
confidence: 99%
“…The high voltage power cables have been widely installed in the context of rapid worldwide urbanization 1 . Owing to the excellent overall performance of cross‐linked polyethylene (XLPE) insulation, the highest operating voltage of AC XLPE cable is up to 500 kV 2 . In recent developments, a ±640 kV DC XLPE cable has been developed and passed the qualification tests 3 .…”
Section: Introductionmentioning
confidence: 99%
“…With growing demand on electric energy, high voltage direct current (HVDC) systems are used to transmit high electric power over long distances (Ghorbani et al , 2014; Zhao et al , 2020; Xiang et al , 2021; Yu et al , 2020). The electric field in DC insulations differ in comparison to the electric field in alternating current (AC) insulations due to the accumulation of space charges.…”
Section: Introductionmentioning
confidence: 99%
“…In electrical power engineering, the reliability of the components and the stability of the power transmission are of top most importance. For this purpose, the design of the HVDC components needs to ensure low electric field values within the total insulation under every circumstances (Zhao et al , 2020). To reduce high field values, field grading techniques are applied.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation