2005
DOI: 10.1016/j.sab.2005.04.003
|View full text |Cite
|
Sign up to set email alerts
|

Simulating systematic errors in X-ray absorption spectroscopy experiments: Sample and beam effects

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 52 publications
0
4
0
Order By: Relevance
“…Solution samples (RQ in CH 2 Cl 2 , RQ in H 2 O + HCl, Me-RQ in H 2 O + HCl, RQ in H 2 O + H 2 O 2 , Me-RQ in H 2 O + H 2 O 2 , and RQ and hemine in HEPES buffer) spectra were recorded in fluorescence mode using a seven-element germanium detector. Potential spectrum distortion induced by self-absorption was estimated using the approach previously described using the LASE software, which was written by one of us, , based on the solid state sample spectra, and it was found to be negligible for such diluted solutions. Spectra were recorded using the same energy grid as above, with an acquisition time of 4 s in the edge region and from 4 to 8 s in the k -scale region; each sample was recorded at least three times.…”
Section: Methodsmentioning
confidence: 99%
“…Solution samples (RQ in CH 2 Cl 2 , RQ in H 2 O + HCl, Me-RQ in H 2 O + HCl, RQ in H 2 O + H 2 O 2 , Me-RQ in H 2 O + H 2 O 2 , and RQ and hemine in HEPES buffer) spectra were recorded in fluorescence mode using a seven-element germanium detector. Potential spectrum distortion induced by self-absorption was estimated using the approach previously described using the LASE software, which was written by one of us, , based on the solid state sample spectra, and it was found to be negligible for such diluted solutions. Spectra were recorded using the same energy grid as above, with an acquisition time of 4 s in the edge region and from 4 to 8 s in the k -scale region; each sample was recorded at least three times.…”
Section: Methodsmentioning
confidence: 99%
“…207,208 The parameters given in Table 3 need specic consideration during simulation. 209,210 Thus, criteria for simulation of EXAFS spectrum [210][211][212] can provide precise bond-length 160,161 and coordination number of shells. 213 Fig.…”
Section: Exafsmentioning
confidence: 99%
“…In this study, we used a fairly simple technique that does not need elaborate calculations but solves the problem of the superimposing elemental spectral lines with a Bayesian deconvolution [29][30][31]. The net intensity of the spectral lines was then normalized with a Compton signal, whose intensity and shape are proportional to the atomic number [32] of the element considered and of the density and composition of the material analyzed.…”
Section: Introductionmentioning
confidence: 99%