2003
DOI: 10.1016/s0021-9673(03)00327-3
|View full text |Cite
|
Sign up to set email alerts
|

Simulated moving bed process with cyclic modulation of the feed concentration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
46
0
3

Year Published

2004
2004
2011
2011

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 105 publications
(50 citation statements)
references
References 13 publications
1
46
0
3
Order By: Relevance
“…1d, while keeping the flow-rates and the column configuration unchanged. It was demonstrated that by cyclic modulation of the feed concentration the productivity can be increased and the eluent consumption can be reduced in a nonlinear separation system; the advantage of ModiCon over SMB was also validated experimentally [Schramn et al, 2003].…”
Section: Comparison Of the Smb Varicol Powerfeed And Modicon Processesmentioning
confidence: 97%
See 2 more Smart Citations
“…1d, while keeping the flow-rates and the column configuration unchanged. It was demonstrated that by cyclic modulation of the feed concentration the productivity can be increased and the eluent consumption can be reduced in a nonlinear separation system; the advantage of ModiCon over SMB was also validated experimentally [Schramn et al, 2003].…”
Section: Comparison Of the Smb Varicol Powerfeed And Modicon Processesmentioning
confidence: 97%
“…Recently, we have been able to verify experimentally in the case of a chiral separation that the PowerFeed process can indeed outperform the SMB process [Zhang et al, 2004]. A third new SMB operation mode, ModiCon, has recently been proposed [Schramn et al, 2002[Schramn et al, , 2003, which is based on the concept of modulating the feed concentration of the SMB process during the switching period, as shown in Fig. 1d, while keeping the flow-rates and the column configuration unchanged.…”
Section: Comparison Of the Smb Varicol Powerfeed And Modicon Processesmentioning
confidence: 99%
See 1 more Smart Citation
“…Further modifications of the simulating moving bed techniques are: the PowerFeed SMB process (Kearney and Hieb, 1992;Kloppenburg and Gills, 1999;Zhang et al, 2003aZhang et al, , 2004a in which the flow rates in the unit are allowed to change during a column switching time following a predefined pattern; in Varicol (Adam et al, 2000, Hombourger et al, 2000Zhang et al, 2002Zhang et al, , 2003bToumi et al, 2003;Pais and Rodrigues, 2003) the basic principle of the process consists of an asynchronous shift of the inlet/outlet lines in a system of multicolumns in a recycle loop; in ModiCon (Schramn et al, 2002(Schramn et al, , 2003, another modification of classical SMB, the flow rate and the column configuration are kept unchanged while modulating the feed concentration during the switching period of the SMB process. Schematic representations of these three processes, i.e., PowerFeed, Varicol and ModiCon, in comparison to the basic SMB system, are shown in Figure 1.…”
Section: Introductionmentioning
confidence: 99%
“…As a result, relatively inefficient columns may be used in SMB yielding satisfactory separation. Recently, more sophisticated modes of operation have been proposed, such as the Varicol (Subramani et al, 2003), ModiCon (Schramm et al, 2002) and Powerfeed (Zhang et al, 2003), which essentially derive from the conventional SMB just described, providing higher resolution and general superior performance.…”
Section: Introductionmentioning
confidence: 99%