Simulated and measured inter-area mode shapes and frequencies in the electrical power system of Great Britain

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…Figure 1 suggests that there was a Hopf bifurcation, but the general interpretation of such events in the power system community is that the oscillations are transient, triggered by a switching event, e.g. [1]. For gene expression this dichotomy has been addressed by [54].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Figure 1 suggests that there was a Hopf bifurcation, but the general interpretation of such events in the power system community is that the oscillations are transient, triggered by a switching event, e.g. [1]. For gene expression this dichotomy has been addressed by [54].…”
Section: Discussionmentioning
confidence: 99%
“…Fig. 1 from [1] shows an example where such a mode of oscillation became clear. This type of oscillation is called 'inter-area'; for a review of oscillations in electrical power flow, see [2].…”
Section: Introductionmentioning
confidence: 97%
“…The multiple input multiple output (MIMO) system from (15) has two inputs, the power reference P 0 and the voltage reference V ref , which are combined in the vector u from (18). The speed deviation ω as well as the output signal of the hydro governor P g are measurable and thus represent suitable output variables of the dynamic system (15).…”
Section: Design Of a Power System Stabilizermentioning
confidence: 99%
“…The larger and the more extensive an interconnected power system is, the more likely is the occurrence of inter-area oscillations [18]. Thereby one generator group oscillates against the other over long transmission lines.…”
Section: Introductionmentioning
confidence: 99%
“…The typical frequency of power oscillations observed is around 0.5 Hz at times of high level of power transfer between Scotland and England [1]. These electromechanical oscillations are monitored by several phasor measurement units (PMUs) which are installed at different sites around the transmission system between Scotland and England to provide information to the transmission system operator (TSO) [2].…”
Section: Introductionmentioning
confidence: 99%