2013
DOI: 10.1080/2093761x.2012.759890
|View full text |Cite
|
Sign up to set email alerts
|

Simplified LCA in skin design: The FB720 case

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(17 citation statements)
references
References 3 publications
0
16
1
Order By: Relevance
“…Wadel et al [46] adopted a simplified LCA in the design of building skins with the specific focus on a modular 'unitised' double skin façade in 2013. The façade is made of hybrid profiles of recycled aluminium and laminated timber, a uniquely produced insulated glass with variable solar factor, and opaque enclosures formed of tempered glass, recycled aluminium, recycled carpet boards, sheep wool as insulation, cellular vapour barrier, and recycled cellulose fibre plaster board [46].…”
Section: Embodied Energy Figuresmentioning
confidence: 99%
See 1 more Smart Citation
“…Wadel et al [46] adopted a simplified LCA in the design of building skins with the specific focus on a modular 'unitised' double skin façade in 2013. The façade is made of hybrid profiles of recycled aluminium and laminated timber, a uniquely produced insulated glass with variable solar factor, and opaque enclosures formed of tempered glass, recycled aluminium, recycled carpet boards, sheep wool as insulation, cellular vapour barrier, and recycled cellulose fibre plaster board [46].…”
Section: Embodied Energy Figuresmentioning
confidence: 99%
“…The façade is made of hybrid profiles of recycled aluminium and laminated timber, a uniquely produced insulated glass with variable solar factor, and opaque enclosures formed of tempered glass, recycled aluminium, recycled carpet boards, sheep wool as insulation, cellular vapour barrier, and recycled cellulose fibre plaster board [46]. The figures assessed throughout the study are embodied energy per area of façade (MJ/m²), and CO 2 emissions (kg CO 2 /m²), where the functional unit is 1 m² of façade with a useful lifespan of 50 years.…”
Section: Embodied Energy Figuresmentioning
confidence: 99%
“…Only two studies exist where DSFs have been examined in detail from a life cycle perspective (de Gracia et al, 2013, Wadel et al, 2013. This alone represents a gap in knowledge with reference to a technology widely used in the AEC industry with a strong belief that it delivers "green" buildings, and is thus able to reduce EIs.…”
Section: Lcas Of Dsfsmentioning
confidence: 99%
“…Additionally, the long lifespan of buildings combined with the change of use during their service life imply lower predictability and higher uncertainty of variables, parameters, and future scenarios. Such difficulties eventually lead to taking a 'reductionist' approach in many recent LCAs, where the term 'simplified' often recurs (Bala et al, 2010, De Benedetti et al, 2010, Malmqvist et al, 2011, Wadel et al, 2013, Zabalza Bribián et al, 2009). …”
Section: Lca In the Architecture Engineering And Construction (Aec) Imentioning
confidence: 99%
See 1 more Smart Citation