1998
DOI: 10.1016/s0168-9002(98)00560-9
|View full text |Cite
|
Sign up to set email alerts
|

Simple range measurement of therapeutic ion beams using visible rays generated in a bare plastic scintillator block

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
6
0

Year Published

2006
2006
2017
2017

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 7 publications
0
6
0
Order By: Relevance
“…The plastic scintillator and CCD camera system has been developed for use in heavy ion beam and proton beam range measurement. ( 11 12 ) We applied a method previously used for a particle beam to quantitatively acquire HDR normalI192r source information.…”
Section: Introductionmentioning
confidence: 99%
“…The plastic scintillator and CCD camera system has been developed for use in heavy ion beam and proton beam range measurement. ( 11 12 ) We applied a method previously used for a particle beam to quantitatively acquire HDR normalI192r source information.…”
Section: Introductionmentioning
confidence: 99%
“…This method has previously been used for measuring the range of proton and carbon particles and also for QA in brachytherapy and diagnostic computed tomography. (22)(23)(24)(25)(26)(27)(28)(29)(30) We investigated combining these simple devices to measure a complex IMRT field, and also examined the feasibility of using this as a tomotherapy QA technique.…”
mentioning
confidence: 99%
“…The plastic scintillator is water-equivalent with a density close to 1.0 g cm −3 and consists of hydrogen and carbon. Therefore, it is expected that the range in a plastic scintillator can be converted to that in water with a minor correction (Fukumura et al 1998). The minor correction is only one conversion factor.…”
Section: Range Measurement Toolmentioning
confidence: 99%
“…Several methods for proton beam dosimetry have been developed: a scintillating-screen (Boon et al 1998(Boon et al , 2000, small scintillator and optical fibre (Sarios et al 2004) and a film (Daftari et al 1999, Piermattei et al 2000. A range measurement method for a heavy ion beam has been developed (Fukumura et al 1998), which consists of a plastic scintillator that has a very fast response and a charge-coupled device (CCD) camera, and can measure the range from the image recorded by the CCD camera. This method reduces the beam time for measurement of the range.…”
Section: Introductionmentioning
confidence: 99%