2013
DOI: 10.1590/s0103-90162013000400007
|View full text |Cite
|
Sign up to set email alerts
|

Simple procedure for nutrient analysis of coffee plant with energy dispersive X-ray fluorescence spectrometry (EDXRF)

Abstract: Nutrient analysis is used to estimate nutrient content of crop plants to manage fertilizer application for sustained crop production. Direct solid analysis of agricultural and environmental samples by energy dispersive X-ray fluorescence spectrometry (EDXRF) was chosen as alternative technique to evaluate the simultaneous multielemental quantification of the most important essential elements in coffee (Coffea arabica L.) plants. Inductively coupled plasma atomic emission spectrometry and certified reference ma… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
24
0
6

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 43 publications
(31 citation statements)
references
References 16 publications
1
24
0
6
Order By: Relevance
“…The detection was performed using a Si (Li) detector cooled with liquid nitrogen. The intensity of the element Ka counts per second (cps/lA) was determined from the sample X-ray spectrum deconvolution using the EDX Shimadzu software package (Tezotto et al, 2013).…”
Section: Energy Dispersive X-ray Fluorescence Spectrometry (Edxrf)mentioning
confidence: 99%
“…The detection was performed using a Si (Li) detector cooled with liquid nitrogen. The intensity of the element Ka counts per second (cps/lA) was determined from the sample X-ray spectrum deconvolution using the EDX Shimadzu software package (Tezotto et al, 2013).…”
Section: Energy Dispersive X-ray Fluorescence Spectrometry (Edxrf)mentioning
confidence: 99%
“…Cd content was determined by ICP-OES (Optima 8300, Perkin Elmer). The contents of P, K, Ca, Mg, Cu, Fe, Mn and Zn were determined by X-ray fluorescence method (EDXRF) analysis as described by Tezotto et al (2013), using samples prepared as loose powder. …”
Section: Content and Nutritional Analysismentioning
confidence: 99%
“…1 The analytical protocol most frequently applied for the determination of macro-and micronutrients in plant materials often requires an a priori test sample decomposition, usually performed by microwave-assisted acid sample dissolution, followed by determination using inductively coupled plasma optical emission spectrometry (ICP OES). 2 Some studies have focused on the use of the direct solid sampling analysis based on X-ray fluorescence spectrometry (XRF), [3][4][5] laser-induced breakdown spectroscopy (LIBS) [6][7][8] or laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) [9][10][11] for assessing the mineral nutrition profile of plants. The most common way of sample presentation by using the aforementioned direct analysis methods involves the interrogation of a previously ground plant material in a pellet form.…”
Section: Introductionmentioning
confidence: 99%
“…Some studies have focused on the use of the direct solid sampling analysis based on X-ray fluorescence spectrometry (XRF), [3][4][5] laser-induced breakdown spectroscopy (LIBS) [6][7][8] or laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) 9-11 for assessing the mineral nutrition profile of plants. The most common way of sample presentation by using the aforementioned direct analysis methods involves the interrogation of a previously ground plant material in a pellet form.…”
mentioning
confidence: 99%