2017
DOI: 10.1039/c7ay01748k
|View full text |Cite
|
Sign up to set email alerts
|

Simple method for the quantitative analysis of thin copolymer films on substrates by infrared spectroscopy using direct calibration

Abstract: Automated baseline estimation followed by least squares fitting of copolymer spectrum allows quantification in terms of comonomer volume fraction.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
9
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 47 publications
1
9
0
Order By: Relevance
“…The results are in agreement with successful polymerization also reported in previous studies. 30 , 31 X-ray photoelectron spectroscopy (XPS) was also used as an additional tool to verify the retention of the PFDA functional groups. Both FT-IR and XPS spectra are reported in the Supporting Information .…”
Section: Resultsmentioning
confidence: 99%
“…The results are in agreement with successful polymerization also reported in previous studies. 30 , 31 X-ray photoelectron spectroscopy (XPS) was also used as an additional tool to verify the retention of the PFDA functional groups. Both FT-IR and XPS spectra are reported in the Supporting Information .…”
Section: Resultsmentioning
confidence: 99%
“…FT-IR spectra (4 cm −1 resolution, in the range 800-4000 cm −1 ) were obtained in transmission mode with a Bruker IFS 66 v/s spectrometer. Data were processed with OriginPro and a software developed by M. Tazreiter et al [24], allowed for the determination of crosslinker content in the coatings.…”
Section: Samples Characterizationmentioning
confidence: 99%
“…The copolymer spectrum was fitted with a linear combination of the corresponding homopolymer absorbance spectra, following the routine explained in ref. [24] The evaluated composition in terms of crosslinker percentage is reported in Figure 1.…”
Section: Characterization Of the Icvd Coatings On Bare Substratesmentioning
confidence: 99%
“…From the fitting of the polymer spectrum with monomer spectra of HEMA and EGDMA, we calculated a chemical composition of 10 ± 2% EGDMA and 90 ± 2% HEMA, as evaluated via program IR_fitter. 33 , 34 …”
Section: Resultsmentioning
confidence: 99%
“…This program allows for the quantification of the amount of each monomer in the copolymer film from the linear combination of the single monomer spectra. Details on this procedure can be found elsewhere …”
Section: Methodsmentioning
confidence: 99%