2010
DOI: 10.1021/ac101921f
|View full text |Cite
|
Sign up to set email alerts
|

Simple Flow Injection Analysis System for Simultaneous Determination of Phenolic Antioxidants with Multiple Pulse Amperometric Detection at a Boron-Doped Diamond Electrode

Abstract: A method for simultaneous determination of butylated hydroxyanisole (BHA) and butylated hydroxytoluene (BHT) in food was developed that uses multiple pulse amperometry (MPA) with flow injection analysis (FIA). Determination of these phenolic antioxidants was carried out with a cathodically pretreated boron-doped diamond electrode and an aqueous ethanolic (30% ethanol, v/v) 10 mmol L⁻¹ KNO₃ solution (pH(cond) = 1.5) as supporting electrolyte. A dual-potential waveform, at E(det1) = 850 mV/200 ms and E(det2) = 1… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
42
0
8

Year Published

2011
2011
2020
2020

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 98 publications
(52 citation statements)
references
References 46 publications
0
42
0
8
Order By: Relevance
“…whether they are predominantly hydrogen or oxygen terminated [21]; the predominance of a termination type can be attained by proper electrochemical pretreatments. This effect of surface termination was observed, for instance, in the determination of additives in food products [22][23][24] and of drugs in pharmaceutical formulations [25][26][27][28], when cathodically pretreated (predominantly hydrogen-terminated) BDD electrodes presented better performances.…”
Section: Introductionmentioning
confidence: 82%
“…whether they are predominantly hydrogen or oxygen terminated [21]; the predominance of a termination type can be attained by proper electrochemical pretreatments. This effect of surface termination was observed, for instance, in the determination of additives in food products [22][23][24] and of drugs in pharmaceutical formulations [25][26][27][28], when cathodically pretreated (predominantly hydrogen-terminated) BDD electrodes presented better performances.…”
Section: Introductionmentioning
confidence: 82%
“…When conventional amperometry is substituted by multiple pulse amperometry, two additional characteristics can be noted: the improved in the selectivity [22][23][24][25] and the possibility of measuring more than one analyte at the same time [26][27][28][29][30]. In addition, this technique also allowed for the use of a potential pulse for the constant cleaning of the electrode surface.…”
Section: Introductionmentioning
confidence: 99%
“…Este trabalho apresenta a determinação simultânea de antioxidantes fenólicos (butil-hidróxi-anisol (BHA) e butil-hidroxitolueno (BHT)) de forma simples e rápida usando eletrodo de trabalho de diamante dopado com boro. 100 Foram aplicados apenas dois pulsos de potenciais na seguinte sequência: +0,85 V/200 ms: oxidação e quantificação direta da BHA sem a interferência de BHT; +1,15 V/200 ms: oxidação de ambos os analitos (BHA e BHT). A quantificação da BHT foi obtida pela diferença entre as respostas amperométricas no segundo (1,15 V) e no primeiro pulso de potencial (+0,85 V).…”
Section: Análise Simultâneaunclassified