2023
DOI: 10.1016/j.foodchem.2022.135383
|View full text |Cite
|
Sign up to set email alerts
|

Simple detection of gluten in wheat-containing food samples of celiac diets with a novel fluorescent nanosensor made of folic acid-based carbon dots through molecularly imprinted technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 32 publications
0
2
0
Order By: Relevance
“…Other studies have achieved very good results while decreasing the detection time, to illustrate, a recent study designed an optical nanosensor for rapid detection of the gluten content of samples containing wheat. They obtained results for the determination coefficient (R2) with 0.995 for folic acid-based-carbon dots molecularly imprinted polymer (FA-CDs-MIP) and 0.903 for FA-CDs none-imprinting polymer (FA-CDs-NIP), within a range of gluten detection of 0.36 to 2.20 µM [51]. They reported less than 4 min as the response time for the florescent nanosensor.…”
Section: Discussionmentioning
confidence: 99%
“…Other studies have achieved very good results while decreasing the detection time, to illustrate, a recent study designed an optical nanosensor for rapid detection of the gluten content of samples containing wheat. They obtained results for the determination coefficient (R2) with 0.995 for folic acid-based-carbon dots molecularly imprinted polymer (FA-CDs-MIP) and 0.903 for FA-CDs none-imprinting polymer (FA-CDs-NIP), within a range of gluten detection of 0.36 to 2.20 µM [51]. They reported less than 4 min as the response time for the florescent nanosensor.…”
Section: Discussionmentioning
confidence: 99%
“…136 Recently, a "TURN-ON" fluorescent sensor was reported based on molecularly imprinted polymer (MIP) conjugated CDs for the detection of gluten in flour samples. 137 An increase in the fluorescence of MIP@CDs was observed in the presence of gluten in the concentration ranging from 0.36 to 2.20 µM. The developed gluten sensing kit demonstrated a response time of 4 minutes with a detection limit of 0.10 µM and hence can be used for commercial applications as well.…”
Section: Fluorescent Sensorsmentioning
confidence: 95%
“…Gluten is a structural protein found primarily in grains and is recognized as a food allergen. In very recent work, a CD‐based MIP sensor was successfully developed for the rapid detection of gluten in bread and flour samples, which showed a linear detection range of 0.36–2.20 µM with a LOD of 0.1 µM (Karamdoust et al., 2023). This fluorescent probe was applied to form a selective response toward template gluten molecules by the inhibition of PET.…”
Section: Applications Of Qds In Food Quality and Safetymentioning
confidence: 99%