2004
DOI: 10.24084/repqj02.215
|View full text |Cite
|
Sign up to set email alerts
|

Simple Control Schme of Three-Level PWM Converter Connecting Wind Turbine with Grid

Abstract: Abstract. This paper proposes a simple direct power control using space vector modulation (DPC-SVM) for three-phase threelevel neutral point clamped (3L-NPC) PWM converter connecting a wind turbine generator with grid. The active and reactive power are used as the control variables instead of the currents applied in conventional control method. Moreover, grid voltage sensors are replaced by a virtual flux (VF) estimator. The theoretical principle of this method as well as the synthesis of the active and reacti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2006
2006
2022
2022

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 11 publications
0
5
0
Order By: Relevance
“…These are the internal current control loop, which controls the grid current, and the external voltage control loop, which controls the DC bus voltage and reactive power. The harmonic elimination and dynamic response of the system are controlled by the current control loop and the power flow balance is controlled by the voltage control loop [27,28].…”
Section: Modeling and Loss Analysis Of A Grid-connected Prdcl Inverte...mentioning
confidence: 99%
“…These are the internal current control loop, which controls the grid current, and the external voltage control loop, which controls the DC bus voltage and reactive power. The harmonic elimination and dynamic response of the system are controlled by the current control loop and the power flow balance is controlled by the voltage control loop [27,28].…”
Section: Modeling and Loss Analysis Of A Grid-connected Prdcl Inverte...mentioning
confidence: 99%
“…The state-space averaging method has been used to obtain the equations of the inverter and then the dqO transformation is carried out to control the inverter in this reference system using PI controllers [27]. The Vd* reference value is defined to generate the desired 11 v,.·ms AC side voltage while V q * is maintained at O.…”
Section: Control Algorithmmentioning
confidence: 99%
“…Despite the higher turbine cost and the production of the harmonics, the variable speed technology is more suitable [9].…”
Section: Choice Of a Generator-converter Combinationmentioning