2010
DOI: 10.1016/j.saa.2010.08.003
|View full text |Cite
|
Sign up to set email alerts
|

Simple and sensitive method for the quantification of total bilirubin in human serum using 3-methyl-2-benzothiazolinone hydrazone hydrochloride as a chromogenic probe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
4
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 18 publications
1
4
0
Order By: Relevance
“…1C). Interestingly, rabbit bile seemed to be the most effective, which is consistent with its nearly two-fold greater concentration (approximately 600 uM) of bilirubin when compared to bile from ox (approximately 250 uM bilirubin in 100 mg/mL whole bile) or human (approximately 400 uM bilirubin, quantification conducted according to [19]). Collectively, this data suggests plumbagin-mediated toxicity can be alleviated by mammalian bile, possibly by the heme catabolite bilirubin.…”
Section: Resultssupporting
confidence: 54%
See 1 more Smart Citation
“…1C). Interestingly, rabbit bile seemed to be the most effective, which is consistent with its nearly two-fold greater concentration (approximately 600 uM) of bilirubin when compared to bile from ox (approximately 250 uM bilirubin in 100 mg/mL whole bile) or human (approximately 400 uM bilirubin, quantification conducted according to [19]). Collectively, this data suggests plumbagin-mediated toxicity can be alleviated by mammalian bile, possibly by the heme catabolite bilirubin.…”
Section: Resultssupporting
confidence: 54%
“…Bilirubin was quantified as described in Nagaraja et al. [19]. Error bars represent ± one standard deviation, n = 3, and (*) denotes a significant (P≤0.05) difference between EHEC and bilirubin samples and bilirubin alone samples.…”
Section: Supporting Informationmentioning
confidence: 99%
“…To discriminate between conjugated and unconjugated bilirubin, caffeine-sodium benzoate is added to the reaction to displace unconjugated bilirubin from albumin and thus release it into solution, where it reacts with diazotized sulfanilic acid. [20,21] The clinical gold standard has several limitations. The test generally corrects for non-specific protein interferences such as immunoglobulins with an averaged plasma protein level that does not take into account inter-and intraindividual differences in plasma protein levels.…”
Section: Clinically Used Bilirubin Assaysmentioning
confidence: 99%
“…This opens up new application prospects for the detection of biomarkers in hybrid materials. Not only that, the performance of the inorganic-organic hybrid sensor HSA-CuNCs is also more stable than those of spectrophotometry, 68 HPLC 69 and enzymatic electrophoresis 70…”
Section: Bilirubinmentioning
confidence: 99%
“…This opens up new application prospects for the detection of biomarkers in hybrid materials. Not only that, the performance of the inorganic–organic hybrid sensor HSA-CuNCs is also more stable than those of spectrophotometry, 68 HPLC 69 and enzymatic electrophoresis 70 in terms of linear range, high selectivity to target products, and anti-interference capabilities; significantly, the detection limit of hybrid sensor is one to two orders of magnitude higher than that of the three traditional methods. These results suggest that the HSA-CuNC inorganic–organic hybrid probe has the potential for applications in determining bilirubin in clinical samples.…”
Section: Detecting Urinary Biomarkers Using Inorganic–organic Hybrid ...mentioning
confidence: 99%