2022
DOI: 10.1016/j.foodchem.2022.132045
|View full text |Cite
|
Sign up to set email alerts
|

Simple and reliable determination of total arsenic and its species in seafood by ICP-MS and HPLC-ICP-MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 35 publications
2
7
0
Order By: Relevance
“…Low EE (0.49-0.78) indicates that a fraction of As is not extracted. Similar results have previously been observed in Atlantic salmon, tuna, herring, pelagic and oily shes (Lischka et al 2013, Hackethal et al 2021, Nawrocka et al 2022, suggesting that the non-extractable compounds in our study are arsenolipids.…”
Section: Arsenic Speciationsupporting
confidence: 92%
“…Low EE (0.49-0.78) indicates that a fraction of As is not extracted. Similar results have previously been observed in Atlantic salmon, tuna, herring, pelagic and oily shes (Lischka et al 2013, Hackethal et al 2021, Nawrocka et al 2022, suggesting that the non-extractable compounds in our study are arsenolipids.…”
Section: Arsenic Speciationsupporting
confidence: 92%
“…As arsenic metabolites in mushrooms include multiple compounds of similar properties, each separation approach has some limitations and cannot satisfy the full range analysis of arsenic species. Therefore, we adopted two HPLC separation columns—an ion exchange column and a hydrophobic column, which allowed us to achieve desirable analysis results [ 20 , 23 ]. The reduced forms of methylated arsenicals were not detected.…”
Section: Discussionmentioning
confidence: 99%
“…Arsenic speciation was assayed by HPLC-ICP-MS according to previously reported procedures with slight modifications [ 15 , 23 , 24 ]. The HPLC system for arsenic speciation consisted of a degasser, an HPLC column oven, an HPLC binary pump and a standard autosampler (NexSar HPLC, Perkin Elmer).…”
Section: Methodsmentioning
confidence: 99%
“…As a comparative method to verify the accuracy of the developed nanosystem, HPLC-ICP/MS was used. As mentioned above, the samples were also prepared following the GB5009.11-2014, while the procedures for HPLC-ICP/MS computer-based determination of As( v ) were based on previously described methods, 20 which used a chromatography system consisting of ICP-MS (7700x, Agilent Technologies, USA) coupled with HPLC (1260, Agilent Technologies, USA) with the following anion exchange columns: an anion exchange guard column (Agilent Technologies part number G3154-65002, PEEK, 4.6 mm × 10 mm polymethacrylate), followed by an As speciation column (Agilent part number G3288-80000, PEEK, 4.6 mm id × 250 mm polymethacrylate) and PRP-X 100 (4.6 × 250 mm, 10 µm, PEEK) (Hamilton, Switzerland) with a PRP-X 100 anion exchange guard column (3 × 8 mm, 10 µm, PEEK) (Hamilton, Switzerland). The mobile phase of 50 mmol NH 4 (CO 3 ) 2 was prepared in a pH 8.5 aqueous solution of 1% (v/v) MetOH and 0.2 mM EDTA, and an equal degree elution method with a flow rate of 0.8 mL min −1 was used in the experiment.…”
Section: Methodsmentioning
confidence: 99%