2014
DOI: 10.1016/j.chemosphere.2013.12.006
|View full text |Cite
|
Sign up to set email alerts
|

Simple and rapid determination of PCDD/Fs in flue gases from various waste incinerators in China using DR-EcoScreen cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
7
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 24 publications
0
7
0
Order By: Relevance
“…As a result, although the BEQ values obtained from DR-EcoScreen assay were 4.10-to 6.07-fold higher than the TEQ values from the HRGC-HRMS analysis, we found good linear relationships (r 2 =0.95 to 0.99, n=18 to 21) between the two methods for four types of samples (Zhou et al 2014). Therefore, we used the total results for the PCDD/F concentrations in the four kinds of flue gas samples obtained from the two methods.…”
Section: Application Of the Dr-ecoscreen Assay To Determine The Pcdd/mentioning
confidence: 45%
See 3 more Smart Citations
“…As a result, although the BEQ values obtained from DR-EcoScreen assay were 4.10-to 6.07-fold higher than the TEQ values from the HRGC-HRMS analysis, we found good linear relationships (r 2 =0.95 to 0.99, n=18 to 21) between the two methods for four types of samples (Zhou et al 2014). Therefore, we used the total results for the PCDD/F concentrations in the four kinds of flue gas samples obtained from the two methods.…”
Section: Application Of the Dr-ecoscreen Assay To Determine The Pcdd/mentioning
confidence: 45%
“…4a, sample cleanup was conducted using two different methods: The cleanup for the DR-EcoScreen assays employed an SPD-600 automated-sample preparation device (Kyoto Electronics Company, Ltd., Kyoto, Japan), whereas the cleanup for the HRGC-HRMS analysis used conventional manual chromatography columns, including a multisilica gel column, an alumina column, and a florisil column (according to the protocol provided by the Japanese Industrial Standards (JIS K0311 1999)). This automated pretreatment system, consisting of a multilayer silica gel column and an alumina column, employs two special techniques (heating multilayer silica gel and automatic solvent substitution) that were able to remove interference from contaminants such as aromatic hydrocarbons and allow direct concentration to a small volume of DMSO solution, potentially reducing human error (Zhou et al 2014).…”
Section: Application Of the Dr-ecoscreen Assay To Determine The Pcdd/mentioning
confidence: 99%
See 2 more Smart Citations
“…Recently, several studies have carried out soil dioxin surveys in various local regions [22,23,24], but only a few studies have used bioassays to determine soil dioxin levels [8,25,26,27,28,29]. A high correlation has been found between dioxin levels measured using the in vitro aryl-hydrocarbon-receptor (AhR) reporter gene assay and dioxin levels measured using chemical assays [8,30,31]. Although it is a fast-screening and semi-quantitative method of measuring dioxin levels in soil, the AhR reporter gene assay has been used in only a few large-scale soil-contamination studies or large-scale surveillances of dioxin-contaminated soil [27,29].…”
Section: Introductionmentioning
confidence: 99%