1993
DOI: 10.1002/bmc.1130070407
|View full text |Cite
|
Sign up to set email alerts
|

Simple analysis of amoxycillin in plasma by high performance liquid chromatography with internal standardization and ultraviolet detection

Abstract: A simple high performance liquid chromatographic method with ultraviolet detection at 229 nm is described for quantitation of amoxycillin in plasma. After deproteination of plasma samples with perchloric acid and adjustment of the pH to 4.9, the supernatant was injected onto a reversed phase C18 column, using acetonitrile:phosphate buffer (0.01 M, pH 7.4) (1:25 v/v) as the mobile phase. Amoxycillin and the internal standard, cefadroxil, were eluted at 23 min and 12 min, respectively, without interference from … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
10
1
2

Year Published

2001
2001
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(14 citation statements)
references
References 16 publications
(9 reference statements)
1
10
1
2
Order By: Relevance
“…A large number of plasma samples (n ϭ 1,152) collected from 48 closely monitored, healthy volunteers in two bioequivalence studies allowed the development and subsequent validation of LSS models by using several different procedures. The results show that the AUC 0-ϱ of amoxicillin, following administration of single oral doses (500 ) for amoxicillin in 11 previously published studies (1,3,7,10,13,14,(17)(18)(19)(20)26), and the corresponding AUC 0-ϱ derived from the three-point LSS model developed for the reference capsule formulation in the present study (Table 3, (Table 2). The statistical principle of parsimony advises in favor of models with fewer parameters; thus, we settled for three-sample regressions for independent estimation of amoxicillin's AUC 0-ϱ .…”
Section: Discussionsupporting
confidence: 58%
See 2 more Smart Citations
“…A large number of plasma samples (n ϭ 1,152) collected from 48 closely monitored, healthy volunteers in two bioequivalence studies allowed the development and subsequent validation of LSS models by using several different procedures. The results show that the AUC 0-ϱ of amoxicillin, following administration of single oral doses (500 ) for amoxicillin in 11 previously published studies (1,3,7,10,13,14,(17)(18)(19)(20)26), and the corresponding AUC 0-ϱ derived from the three-point LSS model developed for the reference capsule formulation in the present study (Table 3, (Table 2). The statistical principle of parsimony advises in favor of models with fewer parameters; thus, we settled for three-sample regressions for independent estimation of amoxicillin's AUC 0-ϱ .…”
Section: Discussionsupporting
confidence: 58%
“…The robustness of the three-point LSS regression equation derived from the capsule formulation data set as a predictor of the plasma amoxicillin AUC 0-ϱ was confirmed when tested on data from 11 published studies (1,3,7,10,13,14,(17)(18)(19)(20)26), encompassing a large range of amoxicillin single doses (250 to 1,000 mg) and AUC 0-ϱ 's (9 to 55 g ⅐ h ⅐ ml Ϫ1 ). This result not only validates our proposed three-point LSS model but also extends its applicability to a variety of experimental conditions, both clinical and analytical, which prevailed in the 11 studies examined.…”
Section: Discussionmentioning
confidence: 83%
See 1 more Smart Citation
“…6,7) This method is as precise as HPLC assay 10,11) ; it has been widely used to determine amoxicillin concentration. 18,19) The tissue wet weight values revealed differences among groups. The reduction in the tissue wet weight verified in group 4 might be due to the high sodium diclofenac anti-inflammatory activity, 12) and inhibition of both leukocyte migration 20) and superoxide production.…”
Section: Discussionmentioning
confidence: 99%
“…Charles ve Chulavatnatol [2] tarafından yapılan çalışmada, amoksisilin plazmada HPLC yöntemi ile UV dedektör kullanılarak miktar tayininin yapılması amaçlanmıştır. 229 nm dalga boyunda çalışılmıştır.…”
Section: Introductionunclassified