2020
DOI: 10.1007/s11468-020-01172-0
|View full text |Cite
|
Sign up to set email alerts
|

Silver Nanocube- and Nanowire-Based SERS Substrates for Ultra-low Detection of PATP and Thiram Molecules

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 36 publications
(15 citation statements)
references
References 57 publications
0
15
0
Order By: Relevance
“…This observation supports that the charge transfer mechanism is particularly significant at low concentrations where analyte molecules have less opportunity to be located near hot spots. [ 21 ] Finite‐difference time‐domain (FDTD) simulation results show that strong hot spots are formed near the gaps between the Ag NWs and GaN NPs with an approximate width of 5 nm (Figure S2 , Supporting Information). Therefore, analytes are less likely to be located near hot spots at extremely low concentrations, which only cover a small area of the substrate.…”
Section: Resultsmentioning
confidence: 99%
“…This observation supports that the charge transfer mechanism is particularly significant at low concentrations where analyte molecules have less opportunity to be located near hot spots. [ 21 ] Finite‐difference time‐domain (FDTD) simulation results show that strong hot spots are formed near the gaps between the Ag NWs and GaN NPs with an approximate width of 5 nm (Figure S2 , Supporting Information). Therefore, analytes are less likely to be located near hot spots at extremely low concentrations, which only cover a small area of the substrate.…”
Section: Resultsmentioning
confidence: 99%
“…The EF was calculated to be about 1 Â 10 6 , which is comparable to the results obtained by other authors who used silver-based SERS substrates for detecting pyridine and thiram molecules. 22,24,41,42 The representative peak for abamectin at 1447 cm À1 was also chosen to study the quantitative detection by monitoring the intensity of this band as a function of the abamectin concentration. Fig.…”
Section: Sers Measurementsmentioning
confidence: 99%
“…Still, the total amount of the S−C−S group in the fungicide mixture was correlated with I 0.5 , where I is the intensity of the SERS signal at 1382 cm −1 . Other recently published papers related to the detection DTFs usually work with thiram as probe analyte using a variety of silver nanomaterials for the SERS effect [ 22 , 23 , 24 ].…”
Section: Advances In Dtfs Detectionmentioning