Silk fibroin and hydroxyapatite segmented coating enhances graft ligamentization and osseointegration processes of the polyethylene terephthalate artificial ligament in vitro and in vivo

Abstract: A silk fibroin and hydroxyapatite segmented coating ligament is fabricated to enhances graft ligamentization and osseointegration processes successfully.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
21
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
9

Relationship

5
4

Authors

Journals

citations
Cited by 23 publications
(21 citation statements)
references
References 27 publications
0
21
0
Order By: Relevance
“…A thinner interface suggests better integration. 4 For evaluating the maturity of the intra-articular portion of the graft (midsubstance), the content of collagen 1 (Col 1) by sirius red staining, as indicated by yellow-red strong birefringence, was viewed by polarized microscopy. 41 A light microscope was used to observe the a-SMA1 area.…”
Section: Histological Experimentsmentioning
confidence: 99%
“…A thinner interface suggests better integration. 4 For evaluating the maturity of the intra-articular portion of the graft (midsubstance), the content of collagen 1 (Col 1) by sirius red staining, as indicated by yellow-red strong birefringence, was viewed by polarized microscopy. 41 A light microscope was used to observe the a-SMA1 area.…”
Section: Histological Experimentsmentioning
confidence: 99%
“…A smaller interface width indicated better and more reliable tendon-bone healing. 7 The tendon-bone interface width was significantly narrower in the AT group than in the HB group from 4 to 12 weeks. These differences indicate that using an autograft for augmentation in ACL reconstruction may promote tendon-bone healing.…”
Section: Discussionmentioning
confidence: 84%
“…As noted in previous studies, a thinner interface suggests better integration. 4,7,8,47 The mean interface width of a sample was calculated by averaging the width at every 30° point of the tunnel cross section from 0° to 360°, and 3 sections were measured per sample. 47 The graft-bone integration parameters were analyzed using a previously validated scoring system.…”
Section: Methodsmentioning
confidence: 99%
“…Using micro-CT and histological analysis, the current study comprehensively evaluated the effects of SV/CS-encapsulated PET-HA ligaments on the osteointegration process in a rat extra-articular model. Although the anterior cruciate ligament reconstruction model likely reflects the clinical situation, one fact should not be neglected: the complex microenvironments within the joint, including the biomechanical factors, as well as the complicated surgical factors, might result in poor reproducibility of the surgery outcome 37. Consequently, this insufficiency in consistency further magnifies the bias in the accuracy of the outcome.…”
Section: Resultsmentioning
confidence: 99%