2019
DOI: 10.1007/s00604-019-3228-9
|View full text |Cite
|
Sign up to set email alerts
|

Silicon quantum dot-coated onto gold nanoparticles as an optical probe for colorimetric and fluorometric determination of cysteine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
17
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 43 publications
(17 citation statements)
references
References 33 publications
0
17
0
Order By: Relevance
“…Colloidal Au sol was synthesized according to previous report. 32,33 In brief, In brief, 100.0 mL HAuCl4 aqueous solution (0.25 mM) was heated to 100 ℃ and kept reflux for several min. 4.0 mL trisodium citrate solution (38.8 mM) was quickly added to the refluxed HAuCl4 solution and the mixture was kept boiling and stirred for an additional 10 min.…”
Section: Construction Of Cea Sandwich-typeimmunosensormentioning
confidence: 99%
“…Colloidal Au sol was synthesized according to previous report. 32,33 In brief, In brief, 100.0 mL HAuCl4 aqueous solution (0.25 mM) was heated to 100 ℃ and kept reflux for several min. 4.0 mL trisodium citrate solution (38.8 mM) was quickly added to the refluxed HAuCl4 solution and the mixture was kept boiling and stirred for an additional 10 min.…”
Section: Construction Of Cea Sandwich-typeimmunosensormentioning
confidence: 99%
“…), [ 6 ] pesticides, and industrial vapors. [ 7–9 ] Typically, colorimetric sensors use dyes, [ 10,11 ] plasmonic gold and silver nanoparticles, [ 12–15 ] semiconductor quantum dots, [ 16,17 ] graphene quantum dots, [ 18–20 ] photonic crystals, [ 21–24 ] and other nanoparticles as reporting agents, which display quantifiable change in color or intensity upon exposure to a specific target. [ 25,26 ] Another issue with industrial and environmental sensing is that the samples often need to be collected from the waste stream or difficult or dangerous to reach areas that make on‐site and in‐situ analysis a big challenge.…”
Section: Introductionmentioning
confidence: 99%
“…Over the past two decades, tremendous progress has been made in the fluorescence sensor region of SiNPs for intrinsic nontoxicity, which are deemed to be suitable alternatives to traditional II-VI quantum dots [10,11]. Previous works have reported the successful use of SiNPs for the detection of Cu 2+ [12], Hg 2+ [13], dopamine [14], heparin [15], 2,4,6-trinitrophenol [16], phosphatase [17], glutathione [18], nitrite [19], chromium [20], cysteine [21], chlorogenic acid [22], and tetracycline [23]. However, there are few studies regarding the use of SiNPs as a probe for the detection of F − ion.…”
Section: Introductionmentioning
confidence: 99%