2021
DOI: 10.1002/srin.202000537
|View full text |Cite
|
Sign up to set email alerts
|

Silicon Determination in Stainless Steels via Inductively Coupled Plasma Optical Emission Spectrometry: An Overview based on Experimental Data

Abstract: Silicon determination on stainless steel alloys via inductively coupled plasma optical emission spectrometry (ICP‐OES) is a topic not yet fully explored in the literature. In the extreme acidic conditions necessary for the dissolution of these samples, phenomena such as polymerization and aggregation of silicon particles may strongly affect the result. A low recovery may be expected if the analytical steps are not properly conducted. Herein, different experimental layouts with certified reference materials are… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 7 publications
(7 reference statements)
0
7
0
Order By: Relevance
“…Calibration regression coefficients when the internal standard was not used were respectable (0.8067-0.9980). However, when the 13 C was used, the regressions improved to 0.9556-0.9993. The worst performing analyte on both occasions was the Cd.…”
Section: Polymers and Compositesmentioning
confidence: 99%
See 4 more Smart Citations
“…Calibration regression coefficients when the internal standard was not used were respectable (0.8067-0.9980). However, when the 13 C was used, the regressions improved to 0.9556-0.9993. The worst performing analyte on both occasions was the Cd.…”
Section: Polymers and Compositesmentioning
confidence: 99%
“…The determination of 13 C is not an easy analysis because it constitutes only 1.1% of natural C. Zakon et al developed a method by which 13 C could be determined in organic compounds (1,2-dibromoethane, 2-chloroethylbenzene and naphthalene) using GC-MC-ICP-MS. 67 The analytes were transferred from the GC instrument through via a heated transfer line with the column reaching the tip of the injector of the torch. 67 Measurements were made in low resolution mode (resolution of $300) and the instrument was tuned on the background signals of 12 C and 13 C (or possibly H 12 C) originating from atmospheric CO 2 or impurities in the argon gas.…”
Section: 23mentioning
confidence: 99%
See 3 more Smart Citations