2021
DOI: 10.1039/d0qm00653j
|View full text |Cite
|
Sign up to set email alerts
|

Silica-supported dual-dye nanoprobes for ratiometric hypoxia sensing

Abstract: Oxygen (O2) levels provide an important parameter in the early-stage diagnosis of cancers and other diseases. Ratiometric optical O2 sensing has attracted much interest due to its better calibration of...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 50 publications
0
6
0
Order By: Relevance
“…The Stern–Volmer constants ( K SV ) were obtained as 449.3 bar −1 , indicating its very high sensitivity to oxygen. [ 23–26,44–51 ] This value is significantly improved in comparison to our previously reported supramolecular polymer‐based oxygen nanoprobe ( K SV = 189.6 bar −1 ). [ 26 ] The limit of detection (LOD) was as low as 0.223 Pa when 0.1% change of the ratiometric emission intensity ratio of BrNpA‐SiNPs in fully deoxygenated and partially oxygenated solutions occurs.…”
Section: Resultsmentioning
confidence: 64%
See 2 more Smart Citations
“…The Stern–Volmer constants ( K SV ) were obtained as 449.3 bar −1 , indicating its very high sensitivity to oxygen. [ 23–26,44–51 ] This value is significantly improved in comparison to our previously reported supramolecular polymer‐based oxygen nanoprobe ( K SV = 189.6 bar −1 ). [ 26 ] The limit of detection (LOD) was as low as 0.223 Pa when 0.1% change of the ratiometric emission intensity ratio of BrNpA‐SiNPs in fully deoxygenated and partially oxygenated solutions occurs.…”
Section: Resultsmentioning
confidence: 64%
“…Particularly, herein using an internal fluorescence standard rather than an external one in ratiometric imaging will result in better sample homogeneity and minimized effect from different dye stabilities. [ 22–25 ]…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Q factor was calculated to be 98.4% (or I 0 / I air = 60.7) for 2TA2TA:PMMA film, which is at the forefront of oxygen sensing performance. [ 4,15,28 ] Furthermore, 2TA2TA:PMMA film shows good reversibility and reproducibility of emission spectra between vacuum and air environment (Figure S19, Supporting Information). In addition, UV light irradiation of 2TA2TA for 32 h did not bring about any change in 1 H NMR spectrum, indicative of the excellent photochemical stability of TA analogues (Figure S20, Supporting Information).…”
Section: Resultsmentioning
confidence: 99%
“…With our long-term interests in quantitative oxygen detection, [36][37][38][39] we report herein a facile molecular engineering strategy by bridging carbazoles with an ethoxysilane as a spacer, namely DCzC2OSi (Figure 1). Importantly, the DCzC2OSi crystals displayed both ultralong lifetime under vacuum (741.5 ms) and oxygen sensitivity.…”
Section: Introductionmentioning
confidence: 99%