2022
DOI: 10.1016/j.egyr.2021.12.024
|View full text |Cite
|
Sign up to set email alerts
|

Significance of fault-current-limiters and parameters optimization in HVDC circuit breakers for increased capacity of VSC-HVDC transmission networks application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 25 publications
0
7
0
Order By: Relevance
“…The UFD maintains low voltage loss while allowing for quick switching. The primary DC breaker cuts the electricity when the mechanical switch is in the open position [53][54][55]. During zero current and low voltage stress, the mechanical switch opens.…”
Section: Hybrid Circuit Breakermentioning
confidence: 99%
See 2 more Smart Citations
“…The UFD maintains low voltage loss while allowing for quick switching. The primary DC breaker cuts the electricity when the mechanical switch is in the open position [53][54][55]. During zero current and low voltage stress, the mechanical switch opens.…”
Section: Hybrid Circuit Breakermentioning
confidence: 99%
“…After remaining in an open state while the main DC breaker opens, the fast disconnector will be exposed During zero current and low voltage stress, the mechanical switch opens. After remaining in an open state while the main DC breaker opens, the fast disconnector will be exposed to the recovery voltage determined by the protection level of the arrester banks first [53][54][55].…”
Section: Hybrid Circuit Breakermentioning
confidence: 99%
See 1 more Smart Citation
“…In 11 , a superconducting element was combined with mechanical DC-CB to analyze the performance and transient behavior of the beaker during faults using EMTP software. Analysis for the sizing process for fault current limiters combined with DC-CB was done in 27 using PSCAD and MATLAB soft-wares. Superconducting fault limiters was combined with various types of HVDC CBs to analyze their impact on the resulting transient behavior in in 29 The benefits from the extended H-bridge design were utilized in 30 where bidirectional current flow through main circuit breaker could be achieved allowing a reliable performance of breaker as confirmed by simulation results using PSCAD 30 .…”
Section: Introductionmentioning
confidence: 99%
“…“ Modeling of the system ” Section presents the modeling of the SF6 current interrupter using the Mayr model upon ATP/EMTP software. The usage of simulation platforms is considered widely common practice in literature as previously mentioned in review in 11 , 14 , 27 , 29 43 . These simulation platforms have proven to be give a reliable and trustable results as accepted in research community.…”
Section: Introductionmentioning
confidence: 99%