“…3.1. Evaluation Index K, the target recovering degree, was adopted in this study [30] as an objective evaluation indicator. The PSNR was used to evaluate the denoising performance of the algorithm cited in this paper and the range image of the algorithm proposed.…”
Section: Evaluation Index and Simulation Verificationmentioning
confidence: 99%
“…3.1. Evaluation Index K, the target recovering degree, was adopted in this study [30] as an objective evaluation indicator. The PSNR was used to evaluate the denoising performance of the algorithm cited in this paper and the range image of the algorithm proposed.…”
Section: Evaluation Index and Simulation Verificationmentioning
confidence: 99%
“…When the APD works at the Geiger‐mode, it has a particularly high capability to detect photons and a single photon can trigger an avalanche that is self‐sustaining to produce a digital pulse 122–124 . Therefore, the Geiger‐mode APD has high sensitivity, low energy requirements of the laser pulse, and a compact size for system integration 52,68,125,126 . Moreover, because the output signal of the Geiger‐mode APD is a digital pulse, the readout circuitry required no amplification and no analog processing module.…”
Section: Pulsed‐laser Three‐dimensional Imaging Flash Lidar Using Apd Arrays Based On the Geiger‐modementioning
confidence: 99%
“…[122][123][124] Therefore, the Geiger-mode APD has high sensitivity, low energy requirements of the laser pulse, and a compact size for system integration. 52,68,125,126 Moreover, because the output signal of the Geiger-mode APD is a digital pulse, the readout circuitry required no amplification and no analog processing module. Additionally, the readout noise can be effectively eliminated.…”
Section: Pulsed-laser Three-dimensional Imaging Flash Lidar Using Apd...mentioning
confidence: 99%
“…The laser wavelength is 1570nm, the pulse energy is 2mJ, the pulse width is less than 10ns, and the measurement distance can reach 3.9 kilometers. Later, in 2020, the team's Ma Le used a 64×64 pixel Gm-APD array LiDAR device to propose the bump hunting combination algorithm to achieve effective noise suppression and image recovery 12 .…”
Section: Introductionmentioning