Si:As IBC IR focal plane arrays for ground-based and space-based astronomy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
12
0

Year Published

2002
2002
2007
2007

Publication Types

Select...
4
4
1

Relationship

3
6

Authors

Journals

citations
Cited by 23 publications
(13 citation statements)
references
References 0 publications
1
12
0
Order By: Relevance
“…It is assumed that detector noise will be dominated by read noise since dark currents below 10 e/pix/s have been routinely achieved for modern mid-IR detector FPAs such as Si:As IBC devices. 5,6 The expected 80% encircled energy distribution over mid-IR wavelengths for SOFIA is estimated to be at least 3 arcsec. Therefore a scale of 1.5 arcsec/pixel will enable critical sampling.…”
Section: Requirementsmentioning
confidence: 99%
“…It is assumed that detector noise will be dominated by read noise since dark currents below 10 e/pix/s have been routinely achieved for modern mid-IR detector FPAs such as Si:As IBC devices. 5,6 The expected 80% encircled energy distribution over mid-IR wavelengths for SOFIA is estimated to be at least 3 arcsec. Therefore a scale of 1.5 arcsec/pixel will enable critical sampling.…”
Section: Requirementsmentioning
confidence: 99%
“…The linearity correction can be done in any number of ways. For the InSb detectors of channels 1 and 2, a relation of the form S = A·t + B·t 2 (2) (where t is exposure time and A and B are constants) was used to fit to the measured DN values. The linearized signal S′ is then given by…”
Section: Linearitymentioning
confidence: 99%
“…These are (1) to study the early universe, (2) to search for and study brown dwarfs and superplanets, (3) to study ultraluminous galaxies and active galactic nuclei, and (4) to discover and study protoplanetary and planetary debris disks. IRAC is a powerful survey instrument because of its high sensitivity, large field, and simultaneous four-color imaging.…”
Section: Introduction 11 Description Of Iracmentioning
confidence: 99%
“…Two adjacent 5.2′×5.2′ fields of view in the Spitzer focal plane are viewed by the four channels in pairs (3.6 and 5.8 μm; 4.5 and 8 μm). All four detector arrays in the camera are 256×256 pixels in size, with the 3.6 and 4.5 μm channels using InSb arrays and the 4.5 and 8 μm channels using Si:As IBC arrays 5,6,7,8,9 . Both detector types have pixels with a size of 30×30 μm, but the Si:As detector material is thicker (50 μm) than in the InSb devices (7 μm).…”
Section: Introductionmentioning
confidence: 99%