2011
DOI: 10.1007/s00192-011-1440-1
|View full text |Cite
|
Sign up to set email alerts
|

Shrinkage and biomechanical evaluation of lightweight synthetics in a rabbit model for primary fascial repair

Abstract: The biomechanical behaviour of the tested lightweights does not mimic that of native controls. Weight reduction does not prevent shrinkage.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
37
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 49 publications
(38 citation statements)
references
References 27 publications
1
37
0
Order By: Relevance
“…TestXpert II software (Zwick GmbH & Co) was used to record measurements. The stiffness (N/mm) in the comfort (lower forces) and stress (higher forces) zone were calculated [21].…”
Section: Biomechanical Testingmentioning
confidence: 99%
“…TestXpert II software (Zwick GmbH & Co) was used to record measurements. The stiffness (N/mm) in the comfort (lower forces) and stress (higher forces) zone were calculated [21].…”
Section: Biomechanical Testingmentioning
confidence: 99%
“…Previously, explant tensile properties have been characterized at the most basic level, reporting only ultimate tensile stress, strain [13] and Young's modulus [12]. However, more recently it has been recognized that a more detailed analysis of the biomechanical properties is required, with non-linear stressstrain curves divided into the regions identified with soft biological tissue [29], as recent studies are now reporting toe and linear region properties [31]. With changes in mesh biomechanical properties in vivo resulting from new biological growth, it is imperative that biological growth is also characterized.…”
Section: Discussionmentioning
confidence: 98%
“…Their size also permits the creation of several defects in the same animal as well as the harvesting of larger tissue specimens (Figs. 2, and 3) [24,25]. Rabbits are known to have a different collagen metabolism from man, which may have an impact on wound healing as well as degradation of acellular collagen matrices [26].…”
Section: Purpose and Design Of Animal Models And Experimentsmentioning
confidence: 99%
“…ruler: 1 mm. Reproduced with permission from [25] folding, or migration. The explant dimensions are used to quantify eventual contraction.…”
Section: Outcome Measures For the Evaluation Of Experimental Explantsmentioning
confidence: 99%
See 1 more Smart Citation