2018
DOI: 10.1364/ol.43.000715
|View full text |Cite
|
Sign up to set email alerts
|

Shot-noise-limited Doppler-broadened noise-immune cavity-enhanced optical heterodyne molecular spectrometry

Abstract: Shot-noise-limited Doppler-broadened (Db) noise-immune cavity-enhanced optical heterodyne molecular spectrometry (NICE-OHMS) has been realized by implementation of balanced detection. A characterization of the system based on Allan-Werle plots of the absorption coefficient, retrieved by fitting a model function to data, shows that the system has a white noise equivalent absorption per unit length per square root of bandwidth of 2.3 × 10 −13 cm −1 Hz −1∕2 , solely 44% above the shot noise limit, and a detection… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
16
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 25 publications
(17 citation statements)
references
References 32 publications
(27 reference statements)
1
16
0
Order By: Relevance
“…A comparison between the panels (a) and (b) shows, in agreement with the results of Ref. [55], that the balanced detection can remove the wide structure of the background that mainly originates from the EOM and deteriorates the long-term performance of Db NICE-OHMS. It shows that it also eliminates the noise from the narrowest etalons (those with smallest FSR), presumed to originate from interference between the output surface of the output fiber of the laser and the f-C.…”
Section: System Evaluation -Reduction Of Influence Of Background Signalssupporting
confidence: 88%
See 3 more Smart Citations
“…A comparison between the panels (a) and (b) shows, in agreement with the results of Ref. [55], that the balanced detection can remove the wide structure of the background that mainly originates from the EOM and deteriorates the long-term performance of Db NICE-OHMS. It shows that it also eliminates the noise from the narrowest etalons (those with smallest FSR), presumed to originate from interference between the output surface of the output fiber of the laser and the f-C.…”
Section: System Evaluation -Reduction Of Influence Of Background Signalssupporting
confidence: 88%
“…1, is, to a large extent, based on that for balanced detection Db NICE-OHMS presented in Ref. [55]. In short, the system is constructed based on an EDFL that operates at around 1534 nm, addressing an acetylene transition at 6518.4858 cm -1 with a line strength of 8.572×10 -21 cm -1 /(mol cm -2 ) and a dipole moment of 8.0 mD.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Of these, only CRDS is calibration-free, while the other techniques require an independent measurement of the cavity finesse to quantify the absorption. Simultaneous information about molecular absorption and dispersion is provided by noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS), which combines cavity enhancement with frequency modulation (FM) [6,7]. However, because of the use of the FM scheme, NICE-OHMS requires calibration using samples with a known concentration.…”
Section: Introductionmentioning
confidence: 99%