Decellularized grafts elicited significantly lower levels of class I and class II HLA antibody formation at 1, 3, and 12 months after implantation than did standard cryopreserved allografts. Early hemodynamic function of decellularized grafts was similar to that of standard cryopreserved allograft valves. Further experience is necessary to determine whether the reduced immunogenicity of decellularized allografts will truly allow tissue ingrowth and improved long-term durability in patients.