2017
DOI: 10.1515/tae-2017-0012
|View full text |Cite
|
Sign up to set email alerts
|

Ship Power System Analysis Based on Safety Aspects

Abstract: -This article analyses the reasons for the reduction of insulating resistance, processes influencing them and isolation diagnostic methods. It provides a short description of electrical safety situation on ships with isolated neutral electrical power systems. It also covers the methods of protecting personnel from electric shock or preventing ignition or arching damage at the fault location with the help of fault current compensation. Principal fault current compensation circuit diagrams are analysed by using … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 5 publications
(6 reference statements)
0
2
0
Order By: Relevance
“…Maritime transportation necessitates the usage of nearly all forms of electrical equipment found in industrial facilities. For example, generators, electric motors, switching and distribution equipment, protective devices, semiconductor converters, voltage transformers and power converters, electrochemical converters -batteries, electrical protection, automatic control and diagnostics, reactive power filters, device power restrictions, drivers, couplings, bushings, various distribution boxes, lighting, heater installations, and so on [39].…”
Section: Electric Shockmentioning
confidence: 99%
See 1 more Smart Citation
“…Maritime transportation necessitates the usage of nearly all forms of electrical equipment found in industrial facilities. For example, generators, electric motors, switching and distribution equipment, protective devices, semiconductor converters, voltage transformers and power converters, electrochemical converters -batteries, electrical protection, automatic control and diagnostics, reactive power filters, device power restrictions, drivers, couplings, bushings, various distribution boxes, lighting, heater installations, and so on [39].…”
Section: Electric Shockmentioning
confidence: 99%
“…-protective grounding; -potential equalization; -unlocking protection; [39,40] -isolation of conductive parts; -electric separation of networks; -use of small voltages; -ground-current power compensation;…”
Section: Noisementioning