2018
DOI: 10.14359/51702234
|View full text |Cite
|
Sign up to set email alerts
|

Shear Strengthening of Concrete Girders Using Carbon Fiber-Reinforced Polymer Sheets and Anchors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
13
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(14 citation statements)
references
References 0 publications
1
13
0
Order By: Relevance
“…The use of vertical FRP strips with FRP spike anchors at the web-flange transitions was explored in study [4]. For the tested configuration, the spike anchor was found to be ineffective in increasing the ultimate failure load.…”
Section: Embedded Frp (Spike) Anchorsmentioning
confidence: 99%
See 3 more Smart Citations
“…The use of vertical FRP strips with FRP spike anchors at the web-flange transitions was explored in study [4]. For the tested configuration, the spike anchor was found to be ineffective in increasing the ultimate failure load.…”
Section: Embedded Frp (Spike) Anchorsmentioning
confidence: 99%
“…A similar configuration combining horizontal FRP strips and spike anchors, as illustrated in Figure 3, proved to be a better solution. With this configuration an increase of 50% in cracking load and 40% in ultimate load was achieved [4]. a) Schematic representation b) Drilled holes for FRP spike anchors Figure 3: FRP shear strengthening configuration with horizontal FRP sheets and spike anchors [4] Another attempt was made to anchor the CFRP at the web-flange transition by cutting a groove and filling it with continuous FRP laminate with epoxy.…”
Section: Embedded Frp (Spike) Anchorsmentioning
confidence: 99%
See 2 more Smart Citations
“…Adhikary and Mutsuyoshi [6] said that the shear strength increased as the depth of carbon fiber sheets and the number of layers increased, and the most efficient rehabilitation between the different wrapping layouts was provided by the vertical U-wrap of the sheet. Likewise, the shear behavior of RC beams strengthened with CFRP was investigated by several studies [1,7,8,9,10], reporting that the CFRP rehabilitation effectiveness on shear resistance was affected by the used shear reinforcement quantity. Taljsten [11] agreed that when CFRP layers are placed perpendicular to the direction of the crack, the RC beams rehabilitation in shear becomes more effective.…”
Section: Introductionmentioning
confidence: 99%