2005
DOI: 10.1061/(asce)1090-0268(2005)9:2(147)
|View full text |Cite
|
Sign up to set email alerts
|

Shear Strength of One-Way Concrete Slabs Reinforced with Fiber-Reinforced Polymer Composite Bars

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
45
0
2

Year Published

2011
2011
2018
2018

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 116 publications
(49 citation statements)
references
References 4 publications
2
45
0
2
Order By: Relevance
“…Based on the previous research studies, the basic effective parameters that affecting the shear capacity of FRP-RC beams are the width of web (b w ), effective depth of beam (d), shear span to depth ratio (a/d), concrete compressive strength (f c ′ ), longitudinal reinforcement ratio (ρ f ) and elastic modulus of FRP bars (E f ) [35,[45][46][47][48][49]. An experimental database of 138 test specimens failed in shear was obtained from different previous investigations [31,36,45,47,[49][50][51][52][53][54][55][56][57][58][59][60][61][62][63][64][65]. During the collection stage, specimens with shear span to depth ratios between 2.4 and 6.5 were included but deeper and slender beams were omitted from the database.…”
Section: Experimental Datamentioning
confidence: 99%
“…Based on the previous research studies, the basic effective parameters that affecting the shear capacity of FRP-RC beams are the width of web (b w ), effective depth of beam (d), shear span to depth ratio (a/d), concrete compressive strength (f c ′ ), longitudinal reinforcement ratio (ρ f ) and elastic modulus of FRP bars (E f ) [35,[45][46][47][48][49]. An experimental database of 138 test specimens failed in shear was obtained from different previous investigations [31,36,45,47,[49][50][51][52][53][54][55][56][57][58][59][60][61][62][63][64][65]. During the collection stage, specimens with shear span to depth ratios between 2.4 and 6.5 were included but deeper and slender beams were omitted from the database.…”
Section: Experimental Datamentioning
confidence: 99%
“…Bu çalışma kapsamında toplam 206 adet FRP donatılı betonarme elemanların kesme dayanımı literatürden elde edilmiş [2,[12][13][14][15][16] Deneysel olarak yüklemeye tabi tutulmuş FRP donatılı betonarme elemanlar dikdörtgen kesitli, a/d oranı 2,5'den büyük, basit mesnetli, simetrik olarak iki noktasal yük etkisi altındaki kiriş ve döşemelerden oluşan elemanlardır. Betonarme elemanların 160 adeti kayma donatısız olup diğer 46 eleman ise FRP donatılı kayma donatısına sahip elemanlardan oluşmaktadır.…”
Section: Deneysel Verilerunclassified
“…In addition to the six new test results from the current investigation, the shear strength results of 128 FRP reinforced concrete elements without stirrups were collected from published literature [7][8][9][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33][34]] to evaluate the current shear design guidelines and calibrate the proposed equation in this study. Only rectangular, simply supported beams and slabs that exhibited shear failure were considered.…”
Section: Experimental Databasementioning
confidence: 99%