2009
DOI: 10.1590/s1678-77572009000300011
|View full text |Cite
|
Sign up to set email alerts
|

Shear bond strength of metallic brackets: influence of saliva contamination

Abstract: Objective:To evaluate the influence of saliva contamination on shear bond strength and the bond failure pattern of 3 adhesive systems (Transbond XT, AdheSE and Xeno III) on orthodontic metallic brackets bonded to human enamel.Material and Methods:Seventy-two permanent human molars were cut longitudinally in a mesiodistal direction, producing seventy-two specimens randomly divided into six groups. Each system was tested under 2 different enamel conditions: no contamination and contaminated with saliva. In T, A … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
13
0
2

Year Published

2011
2011
2018
2018

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 12 publications
(18 citation statements)
references
References 16 publications
3
13
0
2
Order By: Relevance
“…Those in vitro characteristics support the clinical practice through the shear bond strength and ARI scores 23 . The correlation between in vitro and in vivo adhesive/resin interfaces and bond strength tests has been shown elsewhere 25 .…”
Section: Discussionsupporting
confidence: 69%
“…Those in vitro characteristics support the clinical practice through the shear bond strength and ARI scores 23 . The correlation between in vitro and in vivo adhesive/resin interfaces and bond strength tests has been shown elsewhere 25 .…”
Section: Discussionsupporting
confidence: 69%
“…The sample size calculation for each assay was based on previous studies. 19,20 Comparisons of antibacterial activity, degree of conversion, percentage of variation of Knoop hardness, and shear bond strength data were performed with 1-way analysis of variance and Tukey tests. Comparisons of initial and final Knoop hardness values were performed with paired t tests for each group.…”
Section: Discussionmentioning
confidence: 99%
“…Os sistemas adesivos ortodônticos convencionais foram desenvolvidos para serem utilizados em ambiente sem contaminação por umidade, proporcionando uma resistência adesiva apropriada 10,11 . Embora alguns estudos [13][14][15] tenham mostrado que a contaminação por umidade é um fator importante na diminuição da RA de braquetes ortodônticos, outros estudos não encontraram diferença na RA frente à contaminação [16][17][18] . Estes resultados diferentes podem ser atribuídos aos diferentes sistemas adesivos utilizados nos estudos.…”
Section: Discussionunclassified
“…Visando melhorar a colagem de braquetes e acessórios ortodônticos em meio úmido, a indústria odontológica vem desenvolvendo novos adesivos hidrofílicos para que, além de diminuírem os passos clínicos na rotina profissional, sejam resistentes às forças ortodônticas e de mastigação 19 . Estes resultados concordam com outros estudos [16][17][18]21 , comprovando que estes materiais apresentam adequada performance, mesmo quando há contaminação. Estes resultados proporcionam segurança ao clínico, já que o ambiente bucal é extremamente úmido e, mesmo com cuidados de controle da saliva, pode ocorrer esta contaminação durante o procedimento de colagem de braquetes.…”
Section: Discussionunclassified