2022
DOI: 10.3390/nano13010001
|View full text |Cite
|
Sign up to set email alerts
|

Shear Bond Strength and Color Stability of Novel Antibacterial Nanofilled Dental Adhesive Resins

Abstract: Experimental adhesives containing co-doped metaloxide nanoparticles were demonstrated to display strong and long-term antibacterial properties against Streptococcus mutans biofilms. The present study represents an effort to characterize the shear-bond strength (SBS) and color stability (CS) of these novel biomaterials. Experimental adhesives were obtained by dispersing nitrogen and fluorine co-doped titanium dioxide nanoparticles (NF_TiO2, 10%, 20% or 30%, v/v%) into OptiBond Solo Plus (OPTB). Dentin surfaces … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 61 publications
0
2
0
Order By: Relevance
“…There is no direct indication in the application brochure of this device for its use in color measurement of resin‐based materials. However, when other studies in the literature investigating the color changes of resin‐based restorative materials were examined, it was seen that the measurements were made with the VITA Easyshade V (Floriani et al, 2022; Hong et al, 2022; Karakaya & Cengiz, 2017; Savic‐Stankovic et al, 2021). This device was preferred in our study to ensure that the results of our study were comparable.…”
Section: Methodsmentioning
confidence: 99%
“…There is no direct indication in the application brochure of this device for its use in color measurement of resin‐based materials. However, when other studies in the literature investigating the color changes of resin‐based restorative materials were examined, it was seen that the measurements were made with the VITA Easyshade V (Floriani et al, 2022; Hong et al, 2022; Karakaya & Cengiz, 2017; Savic‐Stankovic et al, 2021). This device was preferred in our study to ensure that the results of our study were comparable.…”
Section: Methodsmentioning
confidence: 99%
“…Thirty enamel samples were prepared as described in Section 2.1 with six samples for each group. The shear bond test was performed according to a previously published protocol ( Hong et al, 2022 ). Teeth samples were mounted in an acrylic mold (Ultradent Products, South Jordan, UT, United States) using self-curing resin (Epo Thin 2, Buehler, Lake Bluff, IL, United States), positioning the buccal surface for exposure.…”
Section: Methodsmentioning
confidence: 99%