Abstract: Within the limits of this ex vivo study, it was found that the manufacturing methods (M-wire or traditional NiTi) and kinematics (rotary or reciprocating motion) did not affect the shaping abilities of the systems. The extended file designs of highly tapered NiTi systems (ProTaper, WaveOne) resulted in greater deviations from the original root canal trace and more material removal when compared to less tapered systems (Sendoline S5, GT series X).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0
3

Year Published

2016
2016
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(15 citation statements)
references
References 27 publications
(33 reference statements)
0
12
0
3
Order By: Relevance
“…In this study, simulated canals in resin blocks had been used as an experimental model for assessment of shaping ability of the instruments. These simulated canals are an alternative to the real human extracted teeth and have been used in several studies to test the shaping ability of files [ 10 , 11 ]. Although the major advantage of using extracted human teeth is the reproduction of the clinical situation, the variations in three-dimensional root canal morphology makes standardization difficult [ 12 ].…”
Section: Discussionmentioning
confidence: 99%
“…In this study, simulated canals in resin blocks had been used as an experimental model for assessment of shaping ability of the instruments. These simulated canals are an alternative to the real human extracted teeth and have been used in several studies to test the shaping ability of files [ 10 , 11 ]. Although the major advantage of using extracted human teeth is the reproduction of the clinical situation, the variations in three-dimensional root canal morphology makes standardization difficult [ 12 ].…”
Section: Discussionmentioning
confidence: 99%
“…Ceyhanli ve ark. 23 S-şekilli yapay kanalları kullanarak yaptıkları çalışmada konikliği fazla olan ProTaper ve WaveOne eğelerin konikliği az olan Sendoline S5 ve GT series X eğelerden daha fazla miktarda madde kaldırdıklarını ve daha fazla transportasyona neden olduklarını bildirmişlerdir. Karşılaştırması yapılan eğeler farklı olsa da bu çalışmada da önceki çalışmalarla benzer şe-kilde, S5 eğelerin Mtwo eğelerden daha az genişletme yaptığı ve 5. ölçüm noktası haricinde diğer tüm ölçüm noktalarında, eğimin iç ve dış kısmından daha az madde kaldırdığı ve eğim bölgesinde daha az transportasyon meydana getirdiği saptandı.…”
Section: Discussionunclassified
“…Literature research results reported that the shaping ability of S5 was examined in few studies [6][7][8]. In one study, S5 recorded similar transportation with Reciprocal and twisted file (TF) at the apical part, and greater transportation than TF at the middle part [6].…”
Section: S5 (Sendoline Täby Sweden) Is a New Ni Ti Rotary System Mamentioning
confidence: 99%
“…Taper Universal and wave one and similar transportation with GT series X [7]. The last study was examined canal transportation only in extracted teeth.…”
Section: S5 (Sendoline Täby Sweden) Is a New Ni Ti Rotary System Mamentioning
confidence: 99%