2001
DOI: 10.1177/0310057x0102900610
|View full text |Cite
|
Sign up to set email alerts
|

Sevoflurane Drawover Anaesthesia with Two Oxford Miniature Vaporizers in Series

Abstract: The output of sevoflurane from a drawover system utilizing two Oxford Miniature Vaporizers (OMVs) in series has been shown in bench-testing to be predictable. We have shown that adequate anaesthesia can be achieved with one vaporizer in most situations if an intravenous induction is used. Occasionally a second vaporizer is necessary to deepen the level of anaesthesia. For an inhalational technique to be successful it is necessary to use both vaporizers from the outset. Under these conditions, adequate operatin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2005
2005
2013
2013

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 2 publications
(6 reference statements)
0
6
0
Order By: Relevance
“…Though unavailable to our team, the de livery of vapour anaesthesia via drawover equipment has proven benefi ts over plenum rebreather systems in terms of reduced reliance on heavy or complex ancillary equipment and oxygen supplies 4,5,11,12 and as such has been advocated as suitable for disaster, remote area or military anaes thesia 4,5,[11][12][13] . Indeed, drawover equipment is routinely carried by Aus tralian Defence Force medical teams, with Taylor and co-workers 1 reporting the use of both intravenous ketamine and drawover halothane/isofl urane techniques in over 200 surgical procedures following the 1998 Papua New Guinea tsunami.…”
Section: Discussionmentioning
confidence: 99%
“…Though unavailable to our team, the de livery of vapour anaesthesia via drawover equipment has proven benefi ts over plenum rebreather systems in terms of reduced reliance on heavy or complex ancillary equipment and oxygen supplies 4,5,11,12 and as such has been advocated as suitable for disaster, remote area or military anaes thesia 4,5,[11][12][13] . Indeed, drawover equipment is routinely carried by Aus tralian Defence Force medical teams, with Taylor and co-workers 1 reporting the use of both intravenous ketamine and drawover halothane/isofl urane techniques in over 200 surgical procedures following the 1998 Papua New Guinea tsunami.…”
Section: Discussionmentioning
confidence: 99%
“…Vapour output can be increased by arranging two units in the series and is required for induction with Sevoflurane. [1718] It is very convenient for field use and can be used in series with a self-inflating bag or for halothane induction in series with an EMO[19] [Figure 7]. …”
Section: Classificationmentioning
confidence: 99%
“…Liu & Dhara tested the vaporiser on a flow-bench and suggested that the output should be suitable [8]. Brook and Perndt subsequently used sevoflurane clinically and stated that it was possible to perform an inhalation induction with two vaporisers [9] but the modern penchant for gas induction with sevoflurane has been difficult to satisfy with the TSAA. The OMV was designed when the relatively potent halothane was the volatile agent of choice and maximum outputs are limited when 4 MAC of sevoflurane is the target.…”
Section: Volatile Agents and Gas Inductionmentioning
confidence: 99%