2006
DOI: 10.1053/j.ajkd.2006.06.010
|View full text |Cite
|
Sign up to set email alerts
|

Sestamibi Scintigraphy, Topography, and Histopathology of Parathyroid Glands in Secondary Hyperparathyroidism

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
4
0
2

Year Published

2011
2011
2024
2024

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 22 publications
(7 citation statements)
references
References 22 publications
1
4
0
2
Order By: Relevance
“…We found that the superior PGs tended to have a lighter weight, smaller volume, lower PCNA expression, and lower degree of hyperplasia. Our preoperative 99m Tc-MIBI imaging showed that the degree of visualization of the superior PGs was lower, consistent with previous research (33). This may be due to the effect of hemodynamics, gravity, and a relatively narrow growth area, leading to slower pathological growth in the superior PGs than in the inferior PGs (32).…”
Section: Discussionsupporting
confidence: 89%
“…We found that the superior PGs tended to have a lighter weight, smaller volume, lower PCNA expression, and lower degree of hyperplasia. Our preoperative 99m Tc-MIBI imaging showed that the degree of visualization of the superior PGs was lower, consistent with previous research (33). This may be due to the effect of hemodynamics, gravity, and a relatively narrow growth area, leading to slower pathological growth in the superior PGs than in the inferior PGs (32).…”
Section: Discussionsupporting
confidence: 89%
“…Decreased sensitivity in multigland disease compared with single-gland disease is well recognized for planar and SPECT imaging. The study of Lomonte et al 40 aimed to evaluate the value of dual-phase 99m Tc-sestamibi scintigraphy in preoperative localization of the hyperplastic parathyroid glands in patients with secondary hyperparathyroidism. Their conclusions were that 99m Tc-sestamibi scintigraphy did not show high sensitivity in discovering hyperplastic glands, nevertheless it was of help to discriminate between patients with nodular and diffuse hyperplasia.…”
Section: Parathyroid Scintigraphy With 99m Tc -Sestamibimentioning
confidence: 99%
“…Myocardial cleaning is very slow and almost there is no redistibution after 3-4 h from the injection. It accumulates in the mitochondria of the cell (Lomonte et al, 2006). 99m Tc sestamibi diffuses passively out of the blood and apparently localizes in the mitochondria on the basis of their negative electrical potentials (Beller et al, 1993).…”
Section: Introductionmentioning
confidence: 99%