2019
DOI: 10.1039/c9an01260e
|View full text |Cite
|
Sign up to set email alerts
|

SERS-based immunoassay using gold-patterned array chips for rapid and sensitive detection of dual cardiac biomarkers

Abstract: A gold-patterned array platform has been developed for the ultrasensitive SERS-based detection of cTnI and CK-MB.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
32
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 52 publications
(34 citation statements)
references
References 32 publications
0
32
0
Order By: Relevance
“…The GO/AuNP complexes provided strong SERS enhancement ability and detected cTnI with a 5 pg/mL detection limit (Fu et al, 2019). Similarly, Cheng et al (2019) loaded targets and polyclonal-antibody-conjugated Au@Ag core-shell nanoparticles in a gold-patterned chip that ran as a SERS active template for the ultrasensitive detection of cTnI and CK-MB. The limits of detection were 8.9 pg/mL and 9.7 pg/mL for cTnI and CK-MB, respectively.…”
Section: Surface-enhanced Raman Scattering (Sers)mentioning
confidence: 99%
“…The GO/AuNP complexes provided strong SERS enhancement ability and detected cTnI with a 5 pg/mL detection limit (Fu et al, 2019). Similarly, Cheng et al (2019) loaded targets and polyclonal-antibody-conjugated Au@Ag core-shell nanoparticles in a gold-patterned chip that ran as a SERS active template for the ultrasensitive detection of cTnI and CK-MB. The limits of detection were 8.9 pg/mL and 9.7 pg/mL for cTnI and CK-MB, respectively.…”
Section: Surface-enhanced Raman Scattering (Sers)mentioning
confidence: 99%
“…Cardiac troponin I proteins (cTnIs) have been regarded as specific biomarkers for AMI because cTnIs are released only when myocardial tissues are damaged [1,3]. Therefore, diverse methods have been developed for the sensitive and specific sensing of cTnIs [4][5][6][7][8][9][10][11][12][13][14][15][16]. Typically, cTnIs have been identified by radioimmunoassay and enzyme-linked immunosorbent assay (ELSIA) [6,7].…”
Section: Introductionmentioning
confidence: 99%
“…However, these methods often suffer from limitations such as low sensitivity, poor stability, and the high cost of antibodies. Although several approaches have been recently developed for AMI biomarkers [8][9][10][11][12][13][14][15][16], there is still a need to improve sensing performance for detecting very low levels of cTnIs.…”
Section: Introductionmentioning
confidence: 99%
“…Currently, various methods are available for the detection of cTnI, such as chemiluminescence, luorescence,electrochemical immunoassay and surface-enhanced Raman scattering (SERS)-based sandwich immunoassay platform [16][17][18]. However, chemiluminescence immunoassay requires complex operations, large expenses and time consumption, while luorescence immunoassay is bulky, expensive and requires trained personnel to perform the tests.…”
Section: Introductionmentioning
confidence: 99%