2016
DOI: 10.1016/j.egypro.2016.11.217
|View full text |Cite
|
Sign up to set email alerts
|

Series Resistance Measurement of Solar PV Modules Using Mesh in Real Outdoor Condition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 6 publications
0
3
0
Order By: Relevance
“…Additionally, the hybrid transparent solar module exhibited a series resistance of 2.3 Ω cm 2 (Figure 1g), similar to the series resistance of a commercial c‐Si solar module (2–4 Ω cm 2 ). [ 22,23 ] Furthermore, the FF of the fabricated transparent c‐Si solar module was 74.45%, which was 159% higher than that of the solar module interconnected using only microgrid electrodes with micrometer‐scale interconnection electrodes (Figure 1h and Table 1 ). These results show that the new modularization method effectively reduces carrier collection loss.…”
Section: Resultsmentioning
confidence: 97%
“…Additionally, the hybrid transparent solar module exhibited a series resistance of 2.3 Ω cm 2 (Figure 1g), similar to the series resistance of a commercial c‐Si solar module (2–4 Ω cm 2 ). [ 22,23 ] Furthermore, the FF of the fabricated transparent c‐Si solar module was 74.45%, which was 159% higher than that of the solar module interconnected using only microgrid electrodes with micrometer‐scale interconnection electrodes (Figure 1h and Table 1 ). These results show that the new modularization method effectively reduces carrier collection loss.…”
Section: Resultsmentioning
confidence: 97%
“…One of the most critical aspects influencing PV module performance is series resistance. Some researchers are discovered that the series resistance is affected on the FF and power output of PV modules due to the series resistance has a greater impact on the solar cell's output power than any other parameter [3,5,6]. Also, the 𝑅 𝑠 is reduced the short-circuit current but it didn't influence on the 𝑉 𝑜𝑐 [7].…”
Section: Introductionmentioning
confidence: 99%
“…At present, many common faults or abnormality of PV arrays have been investigated, including the degradation of cell materials, solder corrosion, short-circuit failures, partial shading etc. [2][3][4][5]. These methods can mainly be divided into three categories.…”
Section: Introductionmentioning