2015
DOI: 10.1007/s11306-014-0770-7
|View full text |Cite|
|
Sign up to set email alerts
|

Serially coupling hydrophobic interaction and reversed-phase chromatography with simultaneous gradients provides greater coverage of the metabolome

Abstract: The serial coupling of a reversed-phase liquid chromatography (RPLC) column to a hydrophilic interaction liquid chromatography (HILIC) column has been developed in recent years for the detection of polar and nonpolar metabolites. TCA intermediates, bile acid standards and numerous polar and non-polar metabolites extracted from beer were analysed using a combined RPLC/HILIC method. Non-polar metabolites were retained by the RPLC column. Polar metabolites not retained by the RPLC column were retained and separat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
15
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(15 citation statements)
references
References 14 publications
0
15
0
Order By: Relevance
“…Due to reduced volumetric flow rates and increased ionization efficiency, cLC couples particularly well with ESI-MS. 14 This has led to cLC’s dominance in the fields of proteomics, 510 metabolomics, 3,7,1116 and in vivo determination of neuropeptides. 1721 Combined with gradient elution, peak capacities exceeding 800 22,23 have been achieved.…”
mentioning
confidence: 99%
“…Due to reduced volumetric flow rates and increased ionization efficiency, cLC couples particularly well with ESI-MS. 14 This has led to cLC’s dominance in the fields of proteomics, 510 metabolomics, 3,7,1116 and in vivo determination of neuropeptides. 1721 Combined with gradient elution, peak capacities exceeding 800 22,23 have been achieved.…”
mentioning
confidence: 99%
“…To overcome these problems, Haggarty and colleagues applied a method where a sample is injected onto both, RP and HILIC columns in tandem in a single injection [ 41 ]. To solve the problem with the solvent strength incompatibility between the columns, a high-aqueous mobile phase at low flow rate for the RPLC column and a high-acetonitrile mobile phase at high flow rate for the HILIC column were used [ 39 ].…”
Section: Data Acquisition and Analysismentioning
confidence: 99%
“…This tandem column approach was already successfully applied with quadrupole, time of flight (TOF), and orbitrap mass analyzers [ 39 , 41 , 42 , 43 ]. This method could significantly increase the amount of identified metabolites in a single analytical run, but one disadvantage is that isomers cannot be separated [ 39 ].…”
Section: Data Acquisition and Analysismentioning
confidence: 99%
“…To overcome these limitations, several setups have been developed which combine RP chromatography and HILIC in a single run. A first type of setup uses serial coupling of HILIC and RP columns . Greco et al .…”
Section: Introductionmentioning
confidence: 99%