Order By: Relevance
“…As a testament to the transitory nature of this mechanically induced wound healing response, electrode tracks could not be found in animals after several months when the electrode was inserted and quickly removed [6,13,35,47]. We have shown a similar effect with FDG, since glucose metabolism returned to normal levels within seven days if the microdialysis probe was inserted and immediately removed [39]. Taken together, it appears that injury alone produces a more transient metabolic response while the implant appears to induce a more enduring brain tissue response.…”
Section: Introductionmentioning
confidence: 81%
See 2 more Smart Citations
“…As a testament to the transitory nature of this mechanically induced wound healing response, electrode tracks could not be found in animals after several months when the electrode was inserted and quickly removed [6,13,35,47]. We have shown a similar effect with FDG, since glucose metabolism returned to normal levels within seven days if the microdialysis probe was inserted and immediately removed [39]. Taken together, it appears that injury alone produces a more transient metabolic response while the implant appears to induce a more enduring brain tissue response.…”
Section: Introductionmentioning
confidence: 81%
“…In experimental animals, surgical procedures such as cannulation, electrode placement and microdialysis probe implants are performed routinely in studies of brain organization and function. Studies in our laboratory and others have shown that following these routine surgical procedures, animals undergo dramatic short-term and long-term neurochemical and metabolic changes [5,34,39,41,46].…”
Section: Introductionmentioning
confidence: 95%
See 1 more Smart Citation
“…Indeed, fixing the k′ 2 parameter used in analysis of raw images resulted in a negligible underestimation. To further confirm the argument that FA did not mitigate the signal integrity, we averaged the pixel-wise estimated BP ND values in each VOI [30], in raw and FAcorrected images, and compared them with the values estimated with SRTM2 at the VOI level in raw images. High correlations were found between pixel-wise estimated binding parameters and values estimated with VOI analysis.…”
Section: Discussionmentioning
confidence: 98%
“…At first, time frames of raw dynamic images between 30 and 80 min after tracer injection were averaged, in order to enhance visualization of the different structures and to manually co-register the anatomical data to an MRI and volume-of-interest (VOI) template from rat brain [30] implemented in PMOD software. Then, the co-registration parameters were applied to dynamic raw images and time-activity curves (TACs) were generated from the template VOIs.…”
Section: Image Analysismentioning
confidence: 99%