Serial intracameral visualization of the Ahmed glaucoma valve tube by anterior segment optical coherence tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
22
1
1

Year Published

2013
2013
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(24 citation statements)
references
References 20 publications
0
22
1
1
Order By: Relevance
“…It is also very important to evaluate closed-angle glaucoma secondary to anterior rotation of the ciliary body. Anterior-segment OCT also may be helpful to evaluate the length and position of glaucoma drainage device tubes and their relationship with the corneal endothelium [ 9 ] as well as to evaluate filtering bleb in eyes that have undergone filtration surgery [ 10 , 11 ].…”
Section: Diagnosismentioning
confidence: 99%
“…It is also very important to evaluate closed-angle glaucoma secondary to anterior rotation of the ciliary body. Anterior-segment OCT also may be helpful to evaluate the length and position of glaucoma drainage device tubes and their relationship with the corneal endothelium [ 9 ] as well as to evaluate filtering bleb in eyes that have undergone filtration surgery [ 10 , 11 ].…”
Section: Diagnosismentioning
confidence: 99%
“…В результате работы было установлено, что трубка клапана в отдаленном послеоперационном периоде мигрирует, особенно в глазах с вторичной глаукомой, после сквозной кератопластики и хроническим увеите. Авторы на основании полученных результатов рекомендуют имплантировать клапан Ahmed с достаточным запасом длины трубки в таких глазах для предупреждения смещения трубки в слои склеры и обтурации его просвета [29,30].…”
Section: Introductionunclassified
“…If anterior bowing of the iris is prominent, short tube may be prone to be occluded by the iris. In addition, it has been reported that tube retraction can develop after glaucoma drainage implant surgery (Sarkisian 2009; Lopilly Park et al. 2012).…”
mentioning
confidence: 99%
“…Patients with tube obstructions caused by membrane or pars plana insertion of the tube or who developed postoperative complications that required additional surgical intervention were excluded from the present study. All surgeries were performed using Model FP7 AGVs (New World Medical Inc., Rancho Cucamonga, CA, USA) as described previously (Lopilly Park et al. 2012).…”
mentioning
confidence: 99%
See 1 more Smart Citation