2015
DOI: 10.1002/elan.201500089
|View full text |Cite
|
Sign up to set email alerts
|

Sequential Determination of 13 Elements in Complex Matrices by Stripping Voltammetry with Mixed Complexing Electrolytes

Abstract: This paper presents the determination of 13 elements in a simultaneous and sequential analysis using solochrome violet (SVRS), chloranilic acid (CA), diethylenetriaminepentaacetic acid (DTPA), dimethylglyoxime (DMG), and oxine as complexing electrolytes. The Methods were applied to determine Al3+, Fe3+, Mo6+, Zn2+, Cd2+, Pb2+, Cu2+, Ni2+, Co2+, Tl+, U6+, V5+, and Cr6+ in fertilizers, plant materials, and foodstuffs. The Method was found to be selective and accurate (82.13–119.03 %) for elemental analysis in co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
7
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 39 publications
1
7
0
Order By: Relevance
“…By using the hanging mercury drop electrode (HMDE), C. Locatelli has reported the sequential determination of platinum group metals and lead 44, 45 and the determination of ultra‐trace osmium, ruthenium and iridium 46 in surface water and environmental samples. Recently, the sequential determination of 13 elements was performed in HMDE with mixed complexing electrolytes 47, similarly to C. M. G. van den Berg previous work published in 1997 48. However, because of the toxicity of mercury, regulations may restrict the use of mercury as an electrode material.…”
Section: Introductionmentioning
confidence: 99%
“…By using the hanging mercury drop electrode (HMDE), C. Locatelli has reported the sequential determination of platinum group metals and lead 44, 45 and the determination of ultra‐trace osmium, ruthenium and iridium 46 in surface water and environmental samples. Recently, the sequential determination of 13 elements was performed in HMDE with mixed complexing electrolytes 47, similarly to C. M. G. van den Berg previous work published in 1997 48. However, because of the toxicity of mercury, regulations may restrict the use of mercury as an electrode material.…”
Section: Introductionmentioning
confidence: 99%
“…The determination of thallium using DTPA as a complexing reagent has been well mechanistically described for the electrochemical analysis by voltammetry in liquid and solid matrices [25,41]. The voltammetric approach performed in acetate buffer (pH 4.6) involving an electrochemical preconcentration step followed by a stripping step from the electrode surface allows the sensitive determination of total thallium as Tl(I) [25,42].…”
Section: Determination Of Thallium By Voltammetry In Dietary Supplementsmentioning
confidence: 99%
“…The determination of thallium using DTPA as a complexing reagent has been well mechanistically described for the electrochemical analysis by voltammetry in liquid and solid matrices [25,41]. The voltammetric approach performed in acetate buffer (pH 4.6) involving an electrochemical preconcentration step followed by a stripping step from the electrode surface allows the sensitive determination of total thallium as Tl(I) [25,42]. Concerning the Tl species, Tl(I) is thermodynamically more stable than Tl(III) in almost all environmental and biological systems, while Tl(III) only exists under extremely oxidizing and highly alkaline conditions [43].…”
Section: Determination Of Thallium By Voltammetry In Dietary Supplementsmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the sensitivities of these methods remain poor. The voltammetric response of an electroactive ligand that forms a complex with Al(III) were changed in the presence of Al(III), which provides an indirect electrochemical strategy for the determination of Al(III) [ 9 , 10 , 11 , 12 , 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 ]. There also are a few biosensors developed for Al(III) [ 42 , 43 , 44 ].…”
Section: Introductionmentioning
confidence: 99%