2006
DOI: 10.1016/j.jasms.2006.01.002
|View full text |Cite|
|
Sign up to set email alerts
|

Sequence analysis of alginate-derived oligosaccharides by negative-ion electrospray tandem mass spectrometry

Abstract: Negative-ion electrospray tandem mass spectrometry (ES-MS/MS) with collision-induced dissociation (CID) is attempted for sequence determination of alginate oligosaccharides, derived from polyanionic alginic acid, polymannuronate, and polyguluronate by partial depolymerization using either alginate lyase or mild acid hydrolysis. Sixteen homo-and hetero-oligomeric fragments were obtained after fractionation by gel-filtration and strong anion exchange high performance liquid chromatography. The product-ion spectr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
29
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
6
3
1

Relationship

3
7

Authors

Journals

citations
Cited by 69 publications
(32 citation statements)
references
References 34 publications
(41 reference statements)
1
29
0
Order By: Relevance
“…[18][19][20][21][22] An ionizing method for AOs in the negative mode using ESI-MS/MS was reported by Zhang et al 23) but it was inadequate as to sensitivity in the quadrupole mass spectrometer. To improve sensitivity as to the detection level for AOs, we examined the method of positive ionization by LC-MS/MS.…”
Section: Discussionmentioning
confidence: 99%
“…[18][19][20][21][22] An ionizing method for AOs in the negative mode using ESI-MS/MS was reported by Zhang et al 23) but it was inadequate as to sensitivity in the quadrupole mass spectrometer. To improve sensitivity as to the detection level for AOs, we examined the method of positive ionization by LC-MS/MS.…”
Section: Discussionmentioning
confidence: 99%
“…In the last decade, mass spectrometry has become increasingly important for analysis of carbohydrates, including fast screening (Chai, Luo, Lim, & Lawson, 1998;Dell & Morris, 2001) and detailed sequence analysis due to its high sensitivity, high accuracy and fast processing compared to NMR and various chromatographic methods (Chai, Piskarev, & Lawson, 2002;Chai, Piskarev, Zhang, Lawson, & Kogelberg, 2005;Chai et al, 2006;Harvey, 2005;Kogelberg, Piskarev, Zhang, Lawson, & Chai, 2004;Zhang et al, 2006). Carbohydrates, however, are difficult to analyse because of their structural heterogeneity, labile substituents and linkage isomerism.…”
Section: Mass Spectrometrymentioning
confidence: 99%
“…The eluted plate was stained by dipping in a reagent containing 1 mL of 37.5% HCl, 2 ml of aniline, 10 mL of 85% H 3 PO 3 , 100 mL of ethyl acetate and 2 g diphenylamine) for 3 s and heating at 150°C for 10 s [30].…”
Section: Tlc Conditionsmentioning
confidence: 99%