1961
DOI: 10.1021/ac60179a027
|View full text |Cite
|
Sign up to set email alerts
|

Separation of Uranium by Reversed-Phase Partition Chromatography on a Kel-F Column

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
10
0

Year Published

1963
1963
1998
1998

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 79 publications
(10 citation statements)
references
References 8 publications
(8 reference statements)
0
10
0
Order By: Relevance
“…The U-Pb samples were dissolved in teflon-lined steel autoclaves, as described by Krogh [1973], and separated from 2-ml Bio-Rad 1X8, 100-200 mesh resin columns, using HBr, HC1, and H,•O as eluants. The uranium was further purified, following the tri-n-butyl phosphate coated teflon powder method of Hamlin et al [1961] and then mass spectrometrically determined by the triple Re filament technique as described by the National Bureau of Standards group led by Shields [1966]. The lead samples were purified by an anodic electrodeposition method, and the loading and analysis method closely follows that outlined by Barnes et al [1973].…”
Section: Sample Collection and Experimental Proceduresmentioning
confidence: 99%
“…The U-Pb samples were dissolved in teflon-lined steel autoclaves, as described by Krogh [1973], and separated from 2-ml Bio-Rad 1X8, 100-200 mesh resin columns, using HBr, HC1, and H,•O as eluants. The uranium was further purified, following the tri-n-butyl phosphate coated teflon powder method of Hamlin et al [1961] and then mass spectrometrically determined by the triple Re filament technique as described by the National Bureau of Standards group led by Shields [1966]. The lead samples were purified by an anodic electrodeposition method, and the loading and analysis method closely follows that outlined by Barnes et al [1973].…”
Section: Sample Collection and Experimental Proceduresmentioning
confidence: 99%
“…The experimental results were compared with packings used by other authors, and it was concluded that the TBP-loaded perlite column shows approximately the same selectivity and rapidity (16)(17)(18)(19)(20)(21).…”
Section: Resultsmentioning
confidence: 98%
“…The flask was washed with one milliliter of nitrobenzene, which was then poured Ikuko AKAZA [Vol. 39,No. 3 on the Kel-F powder, all of the excessive solvent being drained through the filter.…”
Section: Resultsmentioning
confidence: 99%
“…Some of them could not retain nitrobenzene containing poly-iodide, while others were affected by the solvent system. However, the Kel-F (polytrifluorochloroethylene) moulding powder recommended by Hamlin et al 3) was found to be very suitable because of its large absorptivity and capacity for the solvent and its strong resistivity against chemical agents. Therefore, this substance was finally chosen for this investigation.…”
mentioning
confidence: 99%