2015
DOI: 10.1039/c4ra16373g
|View full text |Cite
|
Sign up to set email alerts
|

Separation of the molecular motion from different components or phases using projection moving-window 2D correlation FTIR spectroscopy for multiphase and multicomponent polymers

Abstract: This study developed a new analytical method called projection moving-window 2D correlation FTIR spectroscopy to separate the molecular motion of groups generated from different components or phases for multiphase and multicomponent polymers.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 61 publications
0
3
0
Order By: Relevance
“…Figure 3 demonstrates FTIR (left) and Raman (right) analysis of the grafted carbon allotropes revealing some spectral differences. Regarding the chemical composition analyzed by FTIR, for the CNH-based composite (A), a weak C-H out of plane vibrational deformation corresponding to the cyclic aromatic rings is observed at 670.5 cm -1 [36]. Another vibrational out of plane deformation at 805.1 cm -1 arises from three neighboring H atoms in the aromatic ring attached to the carbon nanohorns [37].…”
Section: Materials Characterizationmentioning
confidence: 99%
“…Figure 3 demonstrates FTIR (left) and Raman (right) analysis of the grafted carbon allotropes revealing some spectral differences. Regarding the chemical composition analyzed by FTIR, for the CNH-based composite (A), a weak C-H out of plane vibrational deformation corresponding to the cyclic aromatic rings is observed at 670.5 cm -1 [36]. Another vibrational out of plane deformation at 805.1 cm -1 arises from three neighboring H atoms in the aromatic ring attached to the carbon nanohorns [37].…”
Section: Materials Characterizationmentioning
confidence: 99%
“…The spectra resolution was 4 cm −1 . The generalized 2D correlation analysis was carried out by the 2DCS 6.1 software, developed by Zhou et al 11 …”
Section: Methodsmentioning
confidence: 99%
“…The spectra resolution was 4 cm À1 . The generalized 2D correlation analysis was carried out by the 2DCS 6.1 software, developed by Zhou et al 11 The rubber processing analyzer RPA8000 from Taiwan High Speed Rail Test Instrument Co., Ltd. was used to test the heat curing stage in accordance with GB/T 16584-2009.…”
Section: Characterizationmentioning
confidence: 99%