2014
DOI: 10.1016/j.jchromb.2014.07.025
|View full text |Cite
|
Sign up to set email alerts
|

Separation of porcine parvovirus from bovine serum albumin using PEG–salt aqueous two-phase system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
20
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 22 publications
(21 citation statements)
references
References 53 publications
1
20
0
Order By: Relevance
“…On the other hand, a decrease in the PEG chain length results in less ethylene oxide groups per PEG molecule, for the same concentration of polymer, and hence the top phase will be less hydrophobic . In this sense, Vijayaragavan et al . concluded that hydrophobicity plays a dominant role in the partitioning of porcine parvovirus to the PEG‐rich phase, which was also observed in this study.…”
Section: Resultssupporting
confidence: 82%
See 2 more Smart Citations
“…On the other hand, a decrease in the PEG chain length results in less ethylene oxide groups per PEG molecule, for the same concentration of polymer, and hence the top phase will be less hydrophobic . In this sense, Vijayaragavan et al . concluded that hydrophobicity plays a dominant role in the partitioning of porcine parvovirus to the PEG‐rich phase, which was also observed in this study.…”
Section: Resultssupporting
confidence: 82%
“…The results show that the M13 has a high top phase preference in all systems evaluated (Fig. 2, systems [17][18][19][20][21] with at least 65% of the viral particles recovered in the top phase. The total recovery yields (66.9 ± 1.5 -89.4 ± 5.1%) were higher than those obtained in PEG-salt systems.…”
Section: Partition Behavior and Recovery Of Bacteriophage M13 In Emimmentioning
confidence: 99%
See 1 more Smart Citation
“…The cloud point method was used to obtain the binodal curves Preparation of ATPS Assays. As previously reported in others authors' works on the literature [22,23], the ATPS assays follows a well established methodology. Previously, stocks solutions of PEG and (NH 4 ) 2 SO 4 were prepared by weighing appropriate amounts of reagents on an analytical balance (Shimadzu, AX 200 with an uncertainty of ± 0.0001 g).…”
Section: Methodsmentioning
confidence: 99%
“…On the other hand, ATPS's application in the separation engineering filed, which is named aqueous two-phase extraction (ATPE), has also gained prominence. Because of the distinct advantages over the conventional organic solvent liquid-liquid extraction, such as lower cost, lower toxicity and proper interfacial tension [19], ATPE based on various ATPSs is extensively applied in chemical and biological purification and extraction, e.g., separating metal ions [20][21][22][23], purifying proteins [24][25][26], viruses [27,28] and other biological molecules [29,30]. At the same time, the boom of the discoveries of new ATPSs is responsible for the wider application of ATPE.…”
Section: Introductionmentioning
confidence: 99%