1989
DOI: 10.1021/ac00199a013
|View full text |Cite
|
Sign up to set email alerts
|

Separation of cations by open-tubular column liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

1991
1991
2008
2008

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 39 publications
(9 citation statements)
references
References 23 publications
(20 reference statements)
0
9
0
Order By: Relevance
“…For the 4.6 lm ID PBMA column (estimated coating thickness of 0.1 lm), 100% and 89% of the theoretically expected efficiency was achieved for a 90 cm long column, with 680,000 and 246,000 plates for analytes with k 9 values of 0 and 0.16, respectively. The authors were able to separate alkali and alkaline earth metals in about 4 min and alkali metals as a group in under 90 s, reaching LODs of 0.2 -20 fmol [83]. They also showed separations of various amino acids.…”
Section: As Early As In 1981 Ishii and Takeuchi Demonstratedmentioning
confidence: 93%
See 1 more Smart Citation
“…For the 4.6 lm ID PBMA column (estimated coating thickness of 0.1 lm), 100% and 89% of the theoretically expected efficiency was achieved for a 90 cm long column, with 680,000 and 246,000 plates for analytes with k 9 values of 0 and 0.16, respectively. The authors were able to separate alkali and alkaline earth metals in about 4 min and alkali metals as a group in under 90 s, reaching LODs of 0.2 -20 fmol [83]. They also showed separations of various amino acids.…”
Section: As Early As In 1981 Ishii and Takeuchi Demonstratedmentioning
confidence: 93%
“…Especially when used in IC, the siloxane bonds obtained with alkoxysilane chemistries [82,83] are not acceptable for practical use because of their hydrolytic instability. Recently, Pohl et al have pioneered an approach where diepoxide-amine chemistry can be used to build up a unique hydroxide selective anion exchanger layer by layer [88].…”
Section: As Early As In 1981 Ishii and Takeuchi Demonstratedmentioning
confidence: 99%
“…Müller et al [8,9] have shown that in 2 -10 lm bore capillaries using an ion selective microelectrode as a detector, very good ionic separations are possible, attaining nearly the theoretically calculated N values. However, the preparation of such narrow bore capillary columns has been consistently arduous.…”
Section: Introductionmentioning
confidence: 91%
“…In RP OT-LC, using polyacrylate stationary phases, these amines could only be separated in combination with pre-column derivatization [8]. The use of a cation-exchange layer in OT-LC has been demonstrated before by Mtiller et al [15,16]. However, serious problems were encountered during the coating of the columns.…”
Section: Introductionmentioning
confidence: 99%
“…However, serious problems were encountered during the coating of the columns. Preparation of the stationary phases by means of static coating took at least 6 weeks [15] and a dynamic coating procedure [16] was found difficult to reproduce.…”
Section: Introductionmentioning
confidence: 99%