2000
DOI: 10.1007/bf02490562
|View full text |Cite
|
Sign up to set email alerts
|

Separation of amino acids in plant tissue extracts by capillary zone electrophoresis with indirect UV detection using aromatic carboxylates as background electrolytes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2001
2001
2012
2012

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(12 citation statements)
references
References 28 publications
1
11
0
Order By: Relevance
“…In a typical Arabidopsis phloem sample the major amino acids were Glu, Asp, and Gln, which together accounted for 65.47% of the total amino acids, and the essential amino acids (Arg, His, Val, Ile, Leu, Lys, Met, Phe, Thr) which accounted for 16.27% of the total amino acids. These findings are comparable to those reported in the literature for phloem sap obtained from other plants [18,19,39,40].…”
Section: Application To the Phloem Sap And Honeydew Analysissupporting
confidence: 94%
“…In a typical Arabidopsis phloem sample the major amino acids were Glu, Asp, and Gln, which together accounted for 65.47% of the total amino acids, and the essential amino acids (Arg, His, Val, Ile, Leu, Lys, Met, Phe, Thr) which accounted for 16.27% of the total amino acids. These findings are comparable to those reported in the literature for phloem sap obtained from other plants [18,19,39,40].…”
Section: Application To the Phloem Sap And Honeydew Analysissupporting
confidence: 94%
“…pK a values of underivatized amino acids, deduced from the pH values, as well as the corresponding electrophoretic mobilities were measured using a specially developed program [10]. Indirect UV detection was also used for the analysis of phospho amino acids [11] and amino acids in plants [12] (Fig. 1).…”
Section: Uv Detectionmentioning
confidence: 99%
“…As most of the native amino acids absorb only slightly or not at all ultraviolet light (UV), different detection approaches were used in combination with the CZE and MEKC separation techniques. UV and fluorescence or laser-induced fluorescence (LIF) detection after a suitable precolumn, postcolumn and on-column derivatization with a UV chromophore [8][9][10][11][12][13][14] and fluorophore [7,[15][16][17][18], respectively, direct UV detection at a very low wavelength [19,20], indirect UV detection [21], electrochemical detection [22,23], mass spectrometry [24,25], and some other detection techniques [26,27] were applied to the analyses of amino acids.…”
Section: Introductionmentioning
confidence: 99%