2006
DOI: 10.1016/j.chroma.2006.09.089
|View full text |Cite
|
Sign up to set email alerts
|

Separation and identification of isomeric acidic degradation products of organophosphorus chemical warfare agents by capillary electrophoresis-ion trap mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2007
2007
2016
2016

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(23 citation statements)
references
References 48 publications
0
23
0
Order By: Relevance
“…Conditions: capillary, fusedsilica capillary (L t = 85 cm, id = 50 mm); BGE, 10 mM ammonium acetate (pH 8.8); voltage, 20 kV; detection, MS (ESI, spray needle, 13.5 kV, end plate offset, 2500 V, capillary exit offset, 240 V, skimmer 1 at 220 V, skimmer 2, 210 V), a heat liquid: 75:25:2 by volume) methanol/H 2 0/NH 3. Reprinted from [57] with permission.…”
Section: Explosives and Chemical Warfare Agent Residuesmentioning
confidence: 96%
See 2 more Smart Citations
“…Conditions: capillary, fusedsilica capillary (L t = 85 cm, id = 50 mm); BGE, 10 mM ammonium acetate (pH 8.8); voltage, 20 kV; detection, MS (ESI, spray needle, 13.5 kV, end plate offset, 2500 V, capillary exit offset, 240 V, skimmer 1 at 220 V, skimmer 2, 210 V), a heat liquid: 75:25:2 by volume) methanol/H 2 0/NH 3. Reprinted from [57] with permission.…”
Section: Explosives and Chemical Warfare Agent Residuesmentioning
confidence: 96%
“…The need for fast and sensitive methods to screen large numbers of environmental samples for the presence of explosives and chemical warfare agents ensures a continuing interest in the use of CE in this field [9,40,57,58,77,84,93]. Collins and coworkers [77] investigated the ability to separate nitroaromatic and nitramine explosives in seawater samples using both MEKC and CEC.…”
Section: Explosives and Chemical Warfare Agent Residuesmentioning
confidence: 98%
See 1 more Smart Citation
“…[20]. Sonication with ACN, for example, was used by Groom et al Lagarrigue et al [25] have developed a method for the separation and identification of chemical warfare agent degradation products (five alkylphosphonic acids and five alkyl alkylphosphonic acids) by CE-IT-MS. The relevant instrumental parameters were optimised (Table 1) in order to improve CE selectivity and MS detection.…”
Section: Soils and Sedimentsmentioning
confidence: 99%
“…Outside the field of drug analysis, CE-MS was also applied to the separation and identification of chemical warfare agent degradation products (alchylphosphonic acid and alchyl, alchyl phosphonic acid) in soil extracts [40].…”
Section: Forensic Drugs Toxicants and Dyesmentioning
confidence: 99%