2018
DOI: 10.1167/iovs.17-23692
|View full text |Cite
|
Sign up to set email alerts
|

Sensitivity to Velocity- and Disparity-Based Cues to Motion-In-Depth With and Without Spared Stereopsis in Binocular Visual Impairment

Abstract: In one BVI observer there was preserved sensitivity to IOVD but not CD, though overall only those BVI observers with at least gross stereopsis were able to detect disparity- or velocity-based cues to MID. The results imply that these logically distinct information sources are somehow coupled, and in some cases BVI observers with no stereopsis may still retain sensitivity to IOVD.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 44 publications
0
7
0
Order By: Relevance
“…Participants’ sensitivity to MID in achromatic and isoluminant S-cone CD and IOVD stimuli was measured using dot coherence thresholds. The SNR in MID stimuli was incremented in a Bayesian ψ staircasing procedure (73), within a two-interval forced choice paradigm similar to other MID studies (4, 82). Participants indicated which of the two intervals contained MID, where one interval contained the CD or IOVD stimulus and the other contained the respective control stimulus.…”
Section: Methodsmentioning
confidence: 99%
“…Participants’ sensitivity to MID in achromatic and isoluminant S-cone CD and IOVD stimuli was measured using dot coherence thresholds. The SNR in MID stimuli was incremented in a Bayesian ψ staircasing procedure (73), within a two-interval forced choice paradigm similar to other MID studies (4, 82). Participants indicated which of the two intervals contained MID, where one interval contained the CD or IOVD stimulus and the other contained the respective control stimulus.…”
Section: Methodsmentioning
confidence: 99%
“…The stimuli were similar to those used in previous papers (Kaestner et al, 2019; Maloney et al, 2018). Briefly, MID stimuli consisted of random dot patterns that were designed to experimentally dissociate CD- or IOVD-based mechanisms.…”
Section: Methodsmentioning
confidence: 99%
“…Participants’ 3D vision was tested using the TNO Stereo Test, 19 th edition (Lameris Ootech, NL) to ensure that they had functional stereo-acuity (with thresholds at or below 120 arcsec). This test screens for static depth perception (rather than MID perception) as traditionally defined in clinical settings (see Maloney et al, 2018). During the EEG cap set-up, participants were presented with a demonstration of each of the four stimulus conditions on the VIEWpixx display, whereby the stimuli oscillated towards and away continuously according to the linear ramp.…”
Section: Methodsmentioning
confidence: 99%
“…The stimuli were similar to those used in previous papers (Maloney et al, 2018;Kaestner et al, 2019). Briefly, MID stimuli consisted of random dot patterns that were designed to experimentally dissociate CD-or IOVD-based mechanisms.…”
Section: And Iovd Stimulimentioning
confidence: 99%
“…The strips alternated across the eyes to ensure that they did not coincide on the two retinae (Shioiri et al, 2000(Shioiri et al, , 2008. On the rare occasion when a dot fell near the border of a horizontal strip in the left eye that was close to the dot near the border of the horizontal strip in the right eye, these dots were assigned opposite contrast polarity to disrupt any potential disparity signals (Maloney et al, 2018).…”
Section: And Iovd Stimulimentioning
confidence: 99%